w w w . e l a t i o n l i g h t i n g . c o m
36
PLATINUM PROFILE LED™ User Manual Ver 1
ELATION© PLATINUM SBX™
E R R O R C O D E S
Specifications and features are subject to change without any prior written notice.
ERROR CODE
DESCRIPTION
Prism Er
The Prism movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).
Prism Rot. Er
The Prism Rot. movement is not located in the default position after the reset.
This message will appear after a fixture reset if the gobo wheel’s
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).
BladeR Er
The BladeR movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).