background image

 
 

w w w . e l a t i o n l i g h t i n g . c o m  

 

                                                                                           

13

                          PLATINUM PROFILE LED™ User Manual Ver 1

 

U N D E R S T A N D I N G   D M X  

DMX-512

 

DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and 
controller  manufactures  as  a  form  of  communication  between  intelligent  fixtures 

and controllers. DMX allows all makes and models of different manufactures to be 
linked together and operate from a single controller. This is possible as long as all the 

fixtures and the controller are DMX compliant. A DMX controller sends the DMX data 
instructions  to  the  fixture  allowing  the  user  to  control  the  different  aspects  of  an 

intelligent light. DMX data is sent out as serial data that travels from fixture to fixture 
via data “IN” and data “OUT” XLR terminals located on the fixtures (most controllers 

will only have output jacks).   

 

DMX LINKING 

To  ensure  proper  DMX  data  transmission,  always  use  proper  DMX  cables  and  a 
terminator.  When  using  several  DMX  fixtures  try  to  use  the  shortest  cable  path 

possible. Never split a DMX line with a “Y” style connector. The order in which the 
fixtures  are  connected  in  a  DMX  line  does  not  influence  the  DMX  addressing.  For 

example; a fixture assigned a starting DMX address of 1 may be placed anywhere in 
the DMX chain, at the beginning, at the end, or anywhere in the middle. The DMX 

controller knows to send data assigned to address 1 to that fixture no matter where 
it is located in the DMX chain. The 

PLATINUM  PROFILE  LED

™ can be controlled via 

DMX-512 protocol and the DMX address is set via the control menu. 

 

DATA CABLE (DMX Cable) REQUIREMENTS (For DMX and Master/Slave Operation) 

Your fixture and your DMX controller require a standard 3pin or 5pin XLR connector 
for  data  input  and  data  output  (see  figure  below).  If  you  are  making  your  own 

cables, be sure to use two conductor, shielded digital DMX cable rated at 120 ohms; 
this cable is designed for DMX transmission and may be purchased from your Elation 

dealer or at most professional lighting retailers. Your cables should be made with a 
male and female XLR connector on either end of the cable. Also, remember that a 

DMX line must be daisy chained and cannot be split, unless using an approved DMX 
splitter such as 

Elation’s

 

Opto Branch 4™, Opto Branch 8™, or DMX-Branch/4™.

   

Содержание PLATINUM PROFILE LED

Страница 1: ...PLATINUM PROFILE LED user manual E L A TI ON PLATINUM PROFILE LED user manual...

Страница 2: ...ctive companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or i...

Страница 3: ...N T S General Information 4 Warranty 6 Safety Instructions 7 General Guidelines 8 Fixture Overview 9 Fixture Installation 10 Understanding DMX 13 Fixture Menu 17 DMX Channel Functions And Values 29 Er...

Страница 4: ...g the PLATINUM PROFILE LED by Elation Professional Every PLATINUM PROFILE LED has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for dam...

Страница 5: ...r purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of th...

Страница 6: ...as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professio...

Страница 7: ...lines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used...

Страница 8: ...adjacent surfaces Be sure no air ventilation slots are blocked DO NOT attempt installation and or operation without knowledge how to do so DO NOT permit operation by persons who are not qualified to...

Страница 9: ...X T U R E O V E R V I E W 1 LED Assembly 2 Carrying Handle s 3 LCD Menu Function Display 4 LEFT Button 5 DOWN Button 6 ENTER Button 7 RIGHT Button 8 MODE ESC Button 9 UP Button 10 RJ45 Network IN 11...

Страница 10: ...walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 to 113 F 10 to 45 C Do not use the fixture under...

Страница 11: ...periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixtu...

Страница 12: ...e included omega brackets using a M10 screw fitted through the center hole of the Omega Bracket Be sure to attach the included Safety Cable to the fixture using the safety cable rigging point integrat...

Страница 13: ...line with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed...

Страница 14: ...rovided XLR cable to the female XLR output of your controller and the other side to the male XLR input of the PLATINUM PROFILE LED The diagram below illustrates a typical DMX 512 connection when the f...

Страница 15: ...ATA and DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line Using a line terminator will decrease the possibilities of erratic behav...

Страница 16: ...start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected...

Страница 17: ...on once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a fie...

Страница 18: ...rror Record 10 Pan PERSONALITY Status Settings Address via DMX ON OFF Address Via DMX No DMX Status Close Hold Auto Music Auto Run If No DMX Pan Invert ON OFF Pan Reverse Movement Tilt Invert ON OFF T...

Страница 19: ...Mode DMX Channel Modes Basic Mode Extended Mode User Mode A User Defined Channel Assignment User Mode B User Mode C Edit User Mode Edit User Mode A Max Channel XX PAN CH01 Edits User Defined Channel...

Страница 20: ...each time the fixture is powered OFF INFORMATION Time Information Total Run Time Displays fixture total run time INFORMATION Time Information Last Run Time Displays fixture run time for a given period...

Страница 21: ...of 57 Example 2 If the desired DMX address is 420 set Channel 1 to a value of 7 set Channel 2 to a value of 8 and then set Channel 3 to a value of 164 256 164 420 5 After setting Channel 3 to the desi...

Страница 22: ...MX devices can be operated in one DMX line The RDM protocol sends its own packages in the DMX512 data feed and does not influence conventional devices If DMX splitters are used and RDM control is to b...

Страница 23: ...Select Signal DMX Only Define DMX as the default control of the fixture PERSONALITY Select Signal Art Net on IP2 Define Art Net IP02 as the default control of the fixture PERSONALITY Select Signal Art...

Страница 24: ...Blades to Home Positions RESET FUNCTION Reset Focus Reset only Focus motor to Home Position RESET FUNCTION Reset Others Reset ALL other motors not associated previously listed commands to Home Positio...

Страница 25: ...ate procedure instructions on performing this action are left out of this manual For a first time calibrator please contact our customer support team for step by step instructions USER MODE SET User M...

Страница 26: ...ograms The Master unit sends the 3 program parts in a continuous loop The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to If e g a Slave unit...

Страница 27: ...same program as the master units Press ENTER to confirm Press MODE ESC in order to return to the main menu 4 Program Selection for Edit Program Select Edit Program Press ENTER to confirm Select Edit P...

Страница 28: ...uilt In Programs continued Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program...

Страница 29: ...t 2 3 3 TILT MOVEMENT 8 BIT 0 255 TILT Movement 4 4 TILT MOVEMENT 16 BIT 0 255 Fine Control of TILT Movement 3 5 5 COLOR WHEEL 1 0 20 OPEN WHITE 21 41 DARK RED 42 62 AQUA 63 83 UV FILTER 84 104 PINK 1...

Страница 30: ...6 Shake SLOW to FAST 176 191 Gobo 7 Shake SLOW to FAST 192 255 Clockwise Gobo Wheel Rotation from FAST to SLOW 6 8 10 ROTATING GOBOS INDEX ROTATION GOBO WHEEL 1 0 127 Gobo Indexing 128 189 Clockwise...

Страница 31: ...cro 10 208 215 Prism Gobo Macro 11 216 223 Prism Gobo Macro 12 224 231 Prism Gobo Macro 13 232 239 Prism Gobo Macro 14 240 247 Prism Gobo Macro 15 248 255 Prism Gobo Macro 16 9 11 14 ROTATING PRISM PR...

Страница 32: ...IRIS 0 191 MAX to MIN Diameter 192 223 Pulse Closing FAST to SLOW 224 255 Pulse Closing SLOW to FAST 22 IRIS FINE 0 255 Iris FINE Adjustment 16 18 23 BLADE 1 0 255 OPEN to CLOSE 24 BLADE 1 FINE 0 255...

Страница 33: ...0 194 Blade Macro 12 195 209 Blade Macro 13 210 224 Blade Macro 14 225 239 Blade Macro 15 240 255 Blade Macro 16 23 25 35 PAN TILT MOVEMENT SPEED 0 225 MAX to MIN Speed 226 235 Blackout by Movement 23...

Страница 34: ...the error message 01Er 02Er and 05Er flash repeated 5 times If an error does occur during the initial start up procedure the fixture will self generate a second reset signal and try to realign all th...

Страница 35: ...located in the default position after the reset This message will appear after the reset of the fixture reset if the magnetic indexing circuit malfunctions sensor failed or magnet is missing or there...

Страница 36: ...ective motor or defective motor IC drive on main PCB Prism Rot Er The Prism Rot movement is not located in the default position after the reset This message will appear after a fixture reset if the go...

Страница 37: ...ase refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following p...

Страница 38: ...ism and Macros Electronic Dimming Strobe Motorized Focus Mechanical Iris Frost Filter CONTROL CONNECTIONS 3 DMX Channel Modes 24 26 36 RDM Remote Device Management 6 Button Touch Control Panel Full Co...

Страница 39: ...w w w e l a t i o n l i g h t i n g c o m 39 PLATINUM PROFILE LED User Manual Ver 1 PHOTOMETRIC DATA...

Страница 40: ...ct to change without any prior written notice O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp pending 5RDG DVH RU 3ODWLQXP 3UR OH ELO211 ORD...

Страница 41: ......

Отзывы: