background image

www.elationlighting.com

   

                                4 

 

G E N E R A L   I N F O R M A T I O N

 

INTRODUCTION

 

This  fixture  has  been designed  to  perform  reliably  for  years  when  the  information  in  this 
manual  are  followed.  Please  read  and  understand  all  the  instructions  and  guidelines 
carefully  and  thoroughly  before  operating  this  unit.  This  manual  contains  important 
information regarding safety, installation, use, and maintenance. 

 

UNPACKING 

Each  fixture  has  been  thoroughly  tested  and  shipped  in  perfect  operating  condition. 
Carefully check the outer shipping carton for signs of any damage that may have occurred 
during shipping. If the outer carton appears to be damaged, carefully inspect the fixture for 
damage and be sure all included accessories have arrived intact. In the event damage has 
been found and/or parts are missing, please contact our customer support team for further 
instructions.  Please  do  NOT  return  this  fixture  to  your  dealer  without  first  contacting 
customer support at the number listed below. Please do NOT discard the outer shipping 
carton in the trash. Please recycle whenever possible. 

CUSTOMER SUPPORT 

Elation Professional provides a customer support line to provide set up help and answer 
any  set  up  or  operation  questions.  You  may  also  visit  us  on  the  web  at 

www.elationlighting.com

 for any comments or suggestions. For service related issue please 

contact Elation Professional. 

ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST 

Voice: 323-582-3322

   

 

 

 

Fax: 323-832-9142

 

E-mail: 

[email protected] 

ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET   

Voice: +31 45 546 85 30   

 

 

Fax: +31 45 546 85 96 

E-mail: 

[email protected]

 

WARRANTY REGISTRATION / RETURNS

 

Please register online: 

http://www.elationlighting.com/Login.aspx

 to validate your purchase. 

All  returned  service  items  whether  under  warranty  or  not,  must  be  freight  pre-paid  and 
accompany a return authorization (R.A.) number. The R.A. number must be clearly written 
on the outside of the return package. A brief description of the problem as well as the R.A. 
number  must  also  be  written  down  on  a  piece  of  paper  and  included  in  the  shipping 
container. If the unit is under warranty, you must provide a copy of your proof of purchase 
invoice. Items returned without a R.A. number clearly marked on the outside of the package 
will  be  refused  and  returned  at  customer’s  expense.  You  may  obtain  a  R.A.  number  by 
contacting customer support. 

 

Содержание PIXEL BAR 120IP

Страница 1: ...PIXEL BAR 30IP 60IP 120IP user manual...

Страница 2: ...any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and neglig...

Страница 3: ...n 4 Limited Warranty USA Only 5 Safety Guidelines 6 Maintenance Guidelines 8 Fixture Overview 9 Installation Guidelines 10 Connections and Cables 14 Linking and Control 15 DMX Channel Functions and Va...

Страница 4: ...Elation Professional provides a customer support line to provide set up help and answer any set up or operation questions You may also visit us on the web at www elationlighting com for any comments...

Страница 5: ...ofessional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not...

Страница 6: ...FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURES WARRANTY DAMAGES RESULTING FROM MODIFICA...

Страница 7: ...ata cable or any of its connectors are damaged replace it immediately with a new one DO NOT block the air value on the bottom of the fixture This must remain clean and never blocked When installing fi...

Страница 8: ...all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points duri...

Страница 9: ...e part numbers 3 Sliding Position Adjustable 3 Hole Mounting Yoke Pixel Bar 120IP includes 2 4 Safety Cable Attachment Loop 5 Power Data OUTPUT see Optional Accessories for cable part numbers 6 Magnet...

Страница 10: ...the fixture is NOT suitable for marine and or coastal environment installations Installing this fixture in a marine and or coastal environment may cause corrosion and or excessive wear to the interior...

Страница 11: ...rature range is 4 to 113 F 20 to 45 C DO NOT use the fixture under or above this temperature Fixture should be installed in areas outside walking paths seating areas or away from areas were unauthoriz...

Страница 12: ...mproper installation can result in bodily injury INSTALLATION LOCATION PLANNING Use careful planning to select installation locations of PIXEL BAR IP unit s The maximum distance from the PIXEL DRIVER...

Страница 13: ...ides of the fixture starting on one end of the fixture and then carefully sliding the lens over the length of the top cover It is best to attach the frosted lens covers before mounting the fixture FOR...

Страница 14: ...IN 2 Data PIN 3 CLK clock pin PIN 4 Power CABLES ELATION P BAR IP 4pin 16AWG power data cables are available in various lengths See Optional Accessories for details MAXIMUM CABLE DISTANCES 16AWG The f...

Страница 15: ...per Driver Unit MAX BARS per DRIVER PORT MAX PIXELS per DRIVER PORT MAX BARS per DRIVER UNIT MAX PIXELS per DRIVER UNIT PIXEL BAR 30IP 30 90 34 1020 136 4080 PIXEL BAR 60IP 60 180 17 1020 68 4080 PIXE...

Страница 16: ...0 255 RED 14 14 14 0 255 GREEN 15 15 15 0 255 BLUE 16 16 16 0 255 RED 17 17 17 0 255 GREEN 18 18 18 0 255 BLUE 19 19 19 0 255 RED 20 20 20 0 255 GREEN 21 21 21 0 255 BLUE 22 22 22 0 255 RED 23 23 23...

Страница 17: ...61 0 255 RED 62 62 62 0 255 GREEN 63 63 63 0 255 BLUE 64 64 64 0 255 RED 65 65 65 0 255 GREEN 66 66 66 0 255 BLUE 67 67 67 0 255 RED 68 68 68 0 255 GREEN 69 69 69 0 255 BLUE 70 70 70 0 255 RED 71 71 7...

Страница 18: ...ED 107 107 0 255 GREEN 108 108 0 255 BLUE 109 109 0 255 RED 110 110 0 255 GREEN 111 111 0 255 BLUE 112 112 0 255 RED 113 113 0 255 GREEN 114 114 0 255 BLUE 115 115 0 255 RED 116 116 0 255 GREEN 117 11...

Страница 19: ...1 0 255 RED 152 152 0 255 GREEN 153 153 0 255 BLUE 154 154 0 255 RED 155 155 0 255 GREEN 156 156 0 255 BLUE 157 157 0 255 RED 158 158 0 255 GREEN 159 159 0 255 BLUE 160 160 0 255 RED 161 161 0 255 GRE...

Страница 20: ...N 195 0 255 BLUE 196 0 255 RED 197 0 255 GREEN 198 0 255 BLUE 199 0 255 RED 200 0 255 GREEN 201 0 255 BLUE 202 0 255 RED 203 0 255 GREEN 204 0 255 BLUE 205 0 255 RED 206 0 255 GREEN 207 0 255 BLUE 208...

Страница 21: ...N 240 0 255 BLUE 241 0 255 RED 242 0 255 GREEN 243 0 255 BLUE 244 0 255 RED 245 0 255 GREEN 246 0 255 BLUE 247 0 255 RED 248 0 255 GREEN 249 0 255 BLUE 250 0 255 RED 251 0 255 GREEN 252 0 255 BLUE 253...

Страница 22: ...N 285 0 255 BLUE 286 0 255 RED 287 0 255 GREEN 288 0 255 BLUE 289 0 255 RED 290 0 255 GREEN 291 0 255 BLUE 292 0 255 RED 293 0 255 GREEN 294 0 255 BLUE 295 0 255 RED 296 0 255 GREEN 297 0 255 BLUE 298...

Страница 23: ...N 330 0 255 BLUE 331 0 255 RED 332 0 255 GREEN 333 0 255 BLUE 334 0 255 RED 335 0 255 GREEN 336 0 255 BLUE 337 0 255 RED 338 0 255 GREEN 339 0 255 BLUE 340 0 255 RED 341 0 255 GREEN 342 0 255 BLUE 343...

Страница 24: ...R 30IP SQUARE LENS 19 3 490mm 1 4 35 5mm 3 9 101mm 1 6 lbs 0 72kg PIXEL BAR 30IP ROUND LENS 19 3 490mm 1 4 35 5mm 3 9 101mm 1 6 lbs 0 72kg PIXEL BAR 60IP NO LENS COVER 38 0 967mm 1 3 34mm 3 3 83mm 2 6...

Страница 25: ...by one or more of the following methods Reorient or relocate the device Increase the separation between the device and the receiver Connect the device to anelectricaloutlet ona circuit differentfromw...

Страница 26: ......

Отзывы: