RIGGING 

Overhead rigging requires extensive experience, including amongst others calculating 

working load limits, installation material being used, and periodic safety inspection of all 

installation material and the fixture. If you lack these qualifications, do not attempt the 

installation yourself. Improper installation can result in bodily injury. Fixture is fully 

operational in the specific mounting positions illustrated below. 

 

 

   

 

 

S A F E T Y   C A B L E  

 

ALWAYS ATTACH A SAFETY CABLE 

WHENEVER INSTALLING THIS FIXTURE IN 

A SUSPENDED ENVIRONMENT TO 

ENSURE THE FIXTURE WILL NOT DROP IF 

THE CLAMP FAILS.

 

 

Содержание KL FRESNEL 8

Страница 1: ...KL FRESNEL 8 user manual...

Страница 2: ...per unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ela...

Страница 3: ...ited Warranty USA Only 5 Safety Guidelines 6 Maintenance Guidelines 8 Fixture Overview 9 Installation Guidelines 10 System Menu 14 Manual Dimming and Zoom Control 18 DMX Channel Functions And Values 1...

Страница 4: ...discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Barn Door Gel Frame powerCON TRUE1 Cable Fixture Safety Cable Barn Door Safety Cable CUSTOMER SUPPORT Contact EL...

Страница 5: ...parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warra...

Страница 6: ...ranty and increase the risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSE...

Страница 7: ...m between fixture and other devices or a wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install fix...

Страница 8: ...ized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed ele...

Страница 9: ...in DMX In 3 5pin DMX Out 4 3pin DMX Out 5 powerCON TRUE1 In 6 powerCON TRUE1 Out 7 USB Software Update Port 8 OLED Control Menu Display 9 MODE Button 10 UP Button 11 DOWN Button 12 ENTER Button 13 Man...

Страница 10: ...custom matrix designs to any metal truss structure or placing the fixture s on any surface a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is...

Страница 11: ...o has a top lock that secures these accessories to the fixture Secure the included mini SAFETY CABLE to the BARN DOOR and the top lock 1 Lift up lock on top of fixture and insert GEL FRAME into the fi...

Страница 12: ...y cable rigging point attached to the fixture see the illustration below When mounting this fixture to truss be sure to secure an appropriately rated clamp not included to the yoke using an M10 screw...

Страница 13: ...material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully operational in the specific mount...

Страница 14: ...gh the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN bu...

Страница 15: ...date Port Contact Service DFSE OFF ON Restore Factory Settings Info TimeInfo Current 000 Hours Fixture Run Time From Power ON Total 000 Hours Fixture Total Run Time Last 000 Hours Clear Fixture Last R...

Страница 16: ...Mode Disp Set ADDR Disp CH Salve Set Information to Display on LCD Fan Set Led Fan Auto High Low Set LED Fan Speed Dim Curve Linear Square INV Square S Curve Set Dimmer Curve Mode Frequen 900Hz 1000Hz...

Страница 17: ...17 DIMMER CURVE MODES Dim Curve Select desired DIMMER MODE Standard Stage TV Architectural Theatre Stage2 STAGE 2 DIMMING CURVE MODE ADDED WITH SOFTWARE UPDATE VERSION 1 07...

Страница 18: ...Dimmer Zoom Strobe Manual Control Functions Calibrat PassWord Password 050 Calibrate Zoom Motor PSWD Required to Access Zoom 000 255 NOTE To access the LCD Menu Control Display when locked OFF press...

Страница 19: ...2 DIMMER INTENSITY FINE 000 255 Dimmer FINE Adjustment 2 2 3 SHUTTER STROBE 000 031 LED OFF 032 063 LED ON 064 095 Strobe Effect SLOW to FAST 096 127 LED ON 128 159 Pulse Effect In Sequences 160 191 L...

Страница 20: ...immer FINE Adjustment 2 2 3 SHUTTER STROBE 000 031 LED OFF 032 063 LED ON 064 095 Strobe Effect SLOW to FAST 096 127 LED ON 128 159 Pulse Effect In Sequences 160 191 LED ON 192 223 Random Strobe Effec...

Страница 21: ...ZOOM FINE Adjustment 6 6 DIMMER MODES DIMMER DELAY TIMES 000 020 Standard 021 040 Stage 041 060 TV 061 080 Architectural 081 100 Theatre 101 120 Stage 2 121 Dimmer Delay Time 0 0 seconds 122 Dimmer D...

Страница 22: ...00 Hz 106 110 1000 Hz 111 115 1100 Hz 116 120 1200 Hz 121 125 1300 Hz 126 130 1400 Hz 131 135 1500 Hz 136 140 2500 Hz 141 145 4000 Hz 146 150 5000 Hz 151 155 10 000 Hz 156 160 15 000 Hz 161 165 20 000...

Страница 23: ...K CONTROL CONNECTIONS Manual and DMX Controlled Dimmer and Shutter Dimmer and Zoom Rotary Dials 5 DMX Channel Modes 2 3 3 6 7 4 Button Control Panel LCD Menu Display RDM Remote Device Management Adjus...

Страница 24: ...in accordance with the included instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this...

Страница 25: ...I E S ORDER CODE ITEM QUICK RIG CLAMP Low Profile Quick Release Clamp AC3PDMX5PRO 5 ft 1 5m 3pin PRO DMX Cable AC5PDMX5PRO 5 ft 1 5m 5pin PRO DMX Cable NEU088 3 ft 1m powerCON TRUE1 Power Link Cable...

Страница 26: ......