background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DTW BAR 1000™ 

user manual

 

 

Содержание DTW BAR 1000

Страница 1: ...DTW BAR 1000 user manual...

Страница 2: ...nce of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professio...

Страница 3: ...elines 6 Maintenance Guidelines 8 Fixture Overview 10 Installation Guidelines 11 System Menu 13 Pixel Flip 16 Dynamic DIM to WARM Control Range v1 10 17 DMX Channel Functions and Values v1 02 18 DMX C...

Страница 4: ...discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS powerCON Cable Frost Filter Glare Shield Frost Filter Glare Shield Mounting Screws x3 CUSTOMER SUPPORT Contact EL...

Страница 5: ...f the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include any...

Страница 6: ...nty and increase the risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF...

Страница 7: ...m between fixture and other devices or a wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install fix...

Страница 8: ...thorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed...

Страница 9: ...R V I E W 1 3pin DMX IN 2 powerCON IN 3 RJ45 NET IN 4 LCD Menu Control Display 5 powerCON OUT 6 3pin DMX OUT 7 5pin DMX IN 8 FUSE 9 RJ45 NET OUT 10 Mode Button 11 UP Button 12 DOWN Button 13 ENTER Bu...

Страница 10: ...res for custom matrix designs to any metal truss structure or placing the fixture s on any surface a professional equipment installer MUST be consulted to determine if the metal truss structure or sur...

Страница 11: ...inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury and property damage...

Страница 12: ...each a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field Pressing the ENTER button once more will confirm your setting You...

Страница 13: ...W000 255 CW000 255 A000 255 STR 00 99 Set Warm White Cool White Amber and Strobe Values manually Macros 00 07 Select Internal Color Macro See COLOR MACROS for more details Whitebal WW000 255 CW000 255...

Страница 14: ...Sequence Speed Fade Adjustable 07 FLOW 2 SP00 99 F00 99 All Color Chase Sequence Speed Fade Adjustable 08 FLOW 3 SP00 99 F00 99 All Color Chase Sequence Speed Fade Adjustable 09 FLOW 4 SP00 99 F00 99...

Страница 15: ...AMBER 06 COOL WHITE AMBER 07 WARM WHITE COOL WHITE AMBER NO FUNCTION PIXEL FLIP Select the desired starting LED module and chase direction from one of the following modes below via UP DOWN buttons and...

Страница 16: ...ok as intended even while dimming DMX 20 CHANNEL MODE added with software update v1 10 Channels 1 12 LED pixels 1 12 are used to set the individual LED pixel output levels Note channel 14 Shutter Stro...

Страница 17: ...CH 7 CH 10 CH 12 CH 15 CH 36 CH 41 CH 45 CH N A N A 1 1 0 255 All LEDS 1 12 0 0 255 100 1 1 1 1 1 0 255 COOL WHITE All LEDs 1 12 0 0 255 100 2 2 2 2 2 0 255 WARM WHITE All LEDs 1 12 0 0 255 100 3 3 3...

Страница 18: ...4 4 4 0 255 COOL WHITE LED 2 0 0 255 100 5 5 5 0 255 WARM WHITE LED 2 0 0 255 100 6 6 6 0 255 AMBER LED 2 0 0 255 100 7 7 7 0 255 COOL WHITE LED 3 0 0 255 100 8 8 8 0 255 WARM WHITE LED 3 0 0 255 100...

Страница 19: ...AMBER LED 7 0 0 255 100 22 22 22 0 255 COOL WHITE LED 8 0 0 255 100 23 23 23 0 255 WARM WHITE LED 8 0 0 255 100 24 24 24 0 255 AMBER LED 8 0 0 255 100 25 25 25 0 255 COOL WHITE LED 9 0 0 255 100 26 2...

Страница 20: ...OLOR MACROS 0 30 NO Function 31 61 WARM WHITE 62 92 COOL WHITE 93 123 AMBER 124 154 WARM WHITE COOL WHITE 155 185 WARM WHITE AMBER 186 216 COOL WHITE AMBER 217 247 WW CW AMBER 248 255 NO Function 4 5...

Страница 21: ...1 100 THEATRE 101 255 Default to Unit Setting 8 43 PROGRAM MACROS 0 10 NO Function 11 26 Program 01 27 43 Program 02 44 60 Program 03 61 76 Program 04 77 93 Program 05 94 110 Program 06 111 126 Progra...

Страница 22: ...el Flip setting DMX CHANNEL MODE VALUE FUNCTION 1 CH 2 CH 3 CH 5 CH 6 CH 7 CH 10 CH 12 CH 15 CH 36 CH 41 CH 45 CH 20 CH 72 CH SAME AS V1 02 1 0 255 LED 1 0 0 255 100 2 0 255 LED 2 0 0 255 100 3 0 255...

Страница 23: ...1 0 0 255 100 3 0 255 WARM WHITE LED 1 0 0 255 100 4 0 255 WARM WHITE FINE LED 1 0 0 255 100 5 0 255 AMBER LED 1 0 0 255 100 6 0 255 AMBER FINE LED 1 0 0 255 100 7 0 255 COOL WHITE LED 2 0 0 255 100 8...

Страница 24: ...255 100 18 0 255 AMBER FINE LED 3 0 0 255 100 19 0 255 COOL WHITE LED 4 0 0 255 100 20 0 255 COOL WHITE FINE LED 4 0 0 255 100 21 0 255 WARM WHITE LED 4 0 0 255 100 22 0 255 WARM WHITE FINE LED 4 0 0...

Страница 25: ...255 100 36 0 255 AMBER FINE LED 6 0 0 255 100 37 0 255 COOL WHITE LED 7 0 0 255 100 38 0 255 COOL WHITE FINE LED 7 0 0 255 100 39 0 255 WARM WHITE LED 7 0 0 255 100 40 0 255 WARM WHITE FINE LED 7 0 0...

Страница 26: ...00 54 0 255 AMBER FINE LED 9 0 0 255 100 55 0 255 COOL WHITE LED 10 0 0 255 100 56 0 255 COOL WHITE FINE LED 10 0 0 255 100 57 0 255 WARM WHITE LED 10 0 0 255 100 58 0 255 WARM WHITE FINE LED 10 0 0 2...

Страница 27: ...12 0 0 255 100 72 0 255 AMBER FINE LED 12 0 0 255 100 13 COLOR MACROS 0 30 NO Function 31 61 WARM WHITE 62 92 COOL WHITE 93 123 AMBER 124 154 WARM WHITE COOL WHITE 155 185 WARM WHITE AMBER 186 216 COO...

Страница 28: ...100K 151 175 2 200K 176 200 2 300K 201 225 2 400K 226 255 2 500K 18 CTH CONTROL TEMP HIGH 0 NO Function 1 5 2 500K 6 10 2 600K 11 15 2 700K 16 20 2 800K 21 25 2 900K 26 30 3 000K 31 35 3 100K 36 40 3...

Страница 29: ...ynamic color temperature control by allowing a specific CTH Color Temperature High and CTL Color Temp Low to be set via the fixture s system menu or via DMX control This feature provides smooth DIM to...

Страница 30: ...table Dimming Curve Modes COLOR Cool White Warm White Amber CONTROL CONNECTIONS 14 DMX Channel Modes 72 total channels DMX RDM Kling Net and Art Net Protocol Support 4 Button Touch Control Panel 3 5pi...

Страница 31: ...31 DIMENSIONAL DRAWINGS...

Страница 32: ...eavy Duty Wrap Around Hook Style Clamp SCABLE 60 60 lbs Rating 24 Inch Safety Cable AC3PDMX5PRO 5 ft 1 5m 3pin PRO DMX Cable AC5PDMX5PRO 5 ft 1 5m 5pin PRO DMX Cable CAT005 5 1 5m CAT6 etherCON Cable...

Страница 33: ...ses and can radiate radio frequency energy and if not installed and used in accordance with the included instructions may cause harmful interference to radio communications However there is no guarant...

Страница 34: ......

Отзывы: