Elation DR-512 Скачать руководство пользователя страница 4

Elation Professional  -  www.elationlighting.com -  Page 4

  

Customer Support:

 

Elation Professional

®

 provides a customer support line, to

provide set up help and to answer any question should you encounter problems during
your set up or initial operation. You may also visit us on the web at
www.elationlighting.com for any comments or suggestions. For service related issue
please contact Elation Professional

®

. Service Hours are Monday through Friday 9:00

a.m. to 5:00 p.m. Pacific Standard Time.

Voice:

(323) 582-3322

Fax:  

(323) 582-3108

E-mail: 

[email protected]

Warning

To prevent or reduce the risk of electrical shock or fire, do not expose this

unit to rain or moisture.

Caution

!

 

There are no user serviceable parts inside this unit. Do not attempt any

repairs yourself, doing so will void your manufactures warranty.

Please do not discard the shipping carton in the trash. Please recycle when ever
possible.

Safety Warnings!

•  To reduce the risk of electrical shock or fire, do not expose this unit to rain

or moisture.

•  Do not spill water or other liquids  into or on to your unit.
•  Do not attempt to remove or break off the ground prong from the electrical

cord.   This prong is used to reduce the risk of electrical shock and fire in
case of an   internal short. Do not attempt to operate this unit if the power
cord has been frayed or broken.

•  Disconnect from main power before making any type of connection.
•  Do not remove the cover under any conditions. There are no user serviceable

parts   inside.

•  Always be sure to mount this unit in an area that will allow proper

ventilation. Allow about 6” (15cm) between this device and a wall.

•  Do not attempt to operate this unit, if it becomes damaged.
•  This unit is intended for indoor use only, use of this product outdoors voids

all warranties.

•  During long periods of non-use, disconnect the unit’s main power.
•  Always mount this unit in safe and stable matter.
•  Power cords should be routed so they are not likely to be walked on, pinched

by items placed upon or against them.

•  Cleaning -The fixture should be cleaned only as recommended by the

manufacturer. See page 3 for cleaning details.

•  Heat -The appliance should be situated away from heat sources such as

radiators heat registers, stoves, or other appliances (including amplifiers)
that produce heat.

•  The fixture should be serviced by qualified service personnel when:

A.

 

The power-supply cord or the plug has been damaged.

B.

 

Objects have fallen, or liquid has been spilled into the unit.

C.

 

The unit has been exposed to rain or water.

D.

 

The unit does not appear to operate normally or exhibits a
marked change in performance.

 

Содержание DR-512

Страница 1: ...DR 512 USER INSTRUCTIONS 24 004 1126 Rev 1 0 E mail support elationlighting com Internet www elationlighting com Rev 7 04 ...

Страница 2: ...l and Functions 4 4 1 Front panel 4 4 2 Rear panel 5 5 LCD display 6 6 Operation Modes 6 6 1 Manual mode 6 6 2 AUTOSTART mode 7 6 3 DMX MON mode 7 6 4 DMX TRIGGER mode 8 6 5 PROGRAM mode 8 6 5 1 Recording operation 8 6 5 2 Changing the sequence name 8 6 6 SETUP mode 9 7 External Terminals 10 8 Note Information for usage 10 9 Troubleshooting FAQ 11 10 Specifications 11 ...

Страница 3: ...card 4 sequences I01 I04 Startup Shutdown available for memory 33 sequences E01 E33 available for CF card use Capable of PLAY PAUSE and STOP functions Manual Autostart DMX monitor DMX trigger Program Setup mode 24 25 30 frames SMPTE signal available 32 MB CF card is recommended DMX 3Pin input output SMPTE 3Pinput output 9Pin connector Line remote control recalls PLAY STOP and RECORD functions 2_16...

Страница 4: ... electrical shock and fire in case of an internal short Do not attempt to operate this unit if the power cord has been frayed or broken Disconnect from main power before making any type of connection Do not remove the cover under any conditions There are no user serviceable parts inside Always be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this ...

Страница 5: ...uence names 6 DMX indicator Indicates DMX input When the correspondent LED is on that means DMX input is effective while off means no signal input 7 Mode button Used to select different modes MANUAL AUTOSTART DMX MON DMX TRIGGER PROGRAM and SETUP modes available Each tap will change the mode once 8 STARTUP button Used to activate the STARTUP function Read through the manual for details 9 1 4 Seque...

Страница 6: ...ail in the modes chapter 17 RECORD button In PROGRAM mode the recording of a new sequence can be prepared with the RECORD button In order to do so user should choose a sequence then push the RECORD button and start the recording with the PLAY or PAUSE button 4 2 Rear Panel PUSH PUSH PUSH SMPTE OUT SMPTE IN DMX OUT DMX IN Made in PRC DC INPUT 9 12VDC 500mA Min 1 PLAY 2 SEQ A 3 SEQ B 4 STOP 5 RECORD...

Страница 7: ...ime displays in the bottom right corner of the LCD When the LCD shows __ _ __ Hour Minute Second this means the time of internal storage While __ __ __ __ Hour Minute Second Frame this means the SMPTE time The time display pattern can be switched through Sys Time under SETUP mode 6 Operation modes 6 1 MANUAL mode This mode allows the most freedom to operate this unit The user can select any one of...

Страница 8: ...nt operation can be done manually Pressing the STOP button will SHUTDOWN the STARTUP and SHUTDOWN sequences cannot be operated manually under this mode they can only automatically run after respectively pressing the PLAY and STOP buttons AUTOSTART can be rerun after the unit restarts 6 3 DMX MON mode In this mode DMX signals can be monitored In the case that the DMX signals are disabled this unit ...

Страница 9: ... the unit is receiving a DMX signal when the LED is off the unit is not receiving a DMX signal Press the RECORD button the sequence control will be paused and the correspondent data will be erased Press the PAUSE or PLAY button to record Then press the STOP button to stop the operation at any moment you want Warning during operation please do not turn off the unit otherwise the correspondent recor...

Страница 10: ...XT 5 Format Card Use this submenu to format the CF card Press the NEXT button and then use the UP DOWN buttons to choose Yes or No Y N 6 First Trigger Time this item is related with Smpte Trig and Smpte Rec In this mode the user can see the current recorded Smpte trigger time the First trigger point can be accessed after the Smpte signals have been triggered and the corresponding trigger time has ...

Страница 11: ...ondent sequences under different modes can only be stored through mode switching The STARTUP and SHUTDOWN function is only be available during internal operation During CF card operation the STARTUP and SHUTDOWN functions will be disabled If something goes wrong or malfunctions during operation you can restart the unit by pressing and holding down the SHUTDOWN and RECORD buttons Due to the above o...

Страница 12: ...ecording data under Program mode Cause Because there is no vacant space for recording Recovery Delete useless data to have more space for recording Problem 5 Nothing happens when pushing the STARTUP or SHUTDOWN button Cause These two buttons can t be used freely in every operation mode They can only be used in MANUAL mode DMX TRIGGER mode or PROGRAM mode In other modes they are controlled automati...

Страница 13: ... instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under th...

Страница 14: ...wer Requirement DC 9 12V 500mA min Fuse F 500mA 250V 5_20mm CF Card Requirement Exclusive 32 MB LCD Screen 2_16 characters Dimensions 482_120_44mm Weight approx 1 6 kg Binary coded switch input 0 5V no external voltage 1mA LED output Prg mode LED Record LED Play LED 2V 25mA ...