Elation Professional - www.elationlighting.com - Page 10
or No (Y/N), and press the ENTER button to enter the trigger time setting mode.
I01
_
00:00:00:00
_
00:00:00:00
E01
_
00:00:00:00
_
00:00:00:00
There are 8 Trigger times that our available to change, for sequences
I01~I04
and
sequences
E01~E04.
The interval between two Trigger Times is at least 2 seconds.
If the Trigger time is zero, the Trigger time is not set.
(2)
Smpte Rec:
In this mode you can enable or disable the Smpte Record function.
Press the NEXT button, and then use the UP / DOWN buttons to choose “ON.
(3)
Smpte Frame:
use this submenu to set the frame levels of Smpte time. 24/25/30
frames are available. The preset level must be identical with the frame level of the
received Smpte signals.
(4)
Sys Time:
this submenu is used to set the system time for internal operation or
external operation. Press the NEXT button, and then use the UP / DOWN buttons
to choose the option of “IN” or “EXT”.
(5)
Format Card:
Use this submenu to format the CF card. Press the NEXT button,
and then use the UP / DOWN buttons to choose Yes or No (Y/N.
(6)
First Trigger Time:
this item is related with
Smpte Trig
and
Smpte Rec
. In this
mode, the user can see the current recorded Smpte trigger time. (the First trigger
point can be accessed after the Smpte signals have been triggered and the
corresponding trigger time has been set. The Smpte trigger time can be recorded
only under the condition that not all the DMX levels are at zero.)
(7)
Lock Program:
in this submenu you are able to lock or unlock the PRG mode. The
LCD will show you Yes or No (Y / N) to select one. Choose your option and press
“Enter” to confirm, The LCD will display “
Lock Program!
” or “
Unlock
Program!
”. If
you choose “Y”, the Program mode will be in hidden state.
7
External Terminals
The following flowchart shows, SeqA and SeqB can be used to realize the remote
control upon
I
01/
I
02/
E
01/
E
02. The PLAY, STOP, RECORD buttons can be used to
control the running states.
Some information about Prg-mode LED, Record LED and Play LED:
In PRG mode, the
Prg-mode LED
will be “on”. When the internal
Record LED
is “on”,