9
Protector Ring
1
2
Rotating spout
:
The spout can be rotated to the required posi-
tion. This is useful for JET refuelling, to locate
the nozzle to the filler opening.
Loosen protector ring anti-clockwise,
then
rotate spout to required position and fix
protector ring hand-tight.
Change spout
:
Protector ring must be fixed hand-tight. Unscrew
spout anti-clockwise and substitute with requi-
red new type or size. Hand-tight connection is
sufficient for tight connection.
NOTE: follow local regulations in place. To
avoid misfuelling only spouts should be
used which are assigned for the used fuel.
Inspection of strainer
:
Protector ring must be fixed hand-tight.
Unscrew spout anti-clockwise. Inspect the
strainer while holding it against the light. If a
proper inspection is not possible or cleaning is
necessary, the strainer is removed – see
remarks on right hand side.
Cleaning of strainer
:
Loosen and unscrew protector ring. The strainer
can now be taken out of its seat. Clean by
blowing out with air or in a suitable cleaning bath.
If the strainer ES 418.1 is damaged, replace.
Re-assembling in opposite order, hand-tight.
SPOUT WITH SCREW-IN-CONNECTION (SIC)
Strainer ES 418.1
(160µm / 100 mesh)