Cover all exposed hardware with a towel or paper 
towels. Put a container under reservoirs inlet and 
outlet ports. 

Unscrew one of the G1/4 fitting rings on the 

pump/reservoir combo.  

Gently pull the tube off the fitting and direct it into the 

container. 

 

 

 

Let the water run away into the container 

Keep one tube in the container and gently blow into 

the other tube to additionally drain the system. 

You may need to tilt the whole case in order to get all 

the fluid out of the system. 

 

 

 

The best would be to unplug the pipe from the 
fitting on the radiator. Repeat  

Keep the tubes over the towel to prevent water to 
spill over the hardware 

Dry the tubes and pump with paper towel 

 

Содержание EK

Страница 1: ......

Страница 2: ...ompound grease EN Radiator EN Fans EN Pump reservoir combo EN Pump reservoir holder EN LED lights EN Compression fittings EN CPU mounting mechanism EN Coolant EN Tube EN ATX Bridging Plug EN Fan cable...

Страница 3: ......

Страница 4: ...ket motherboards Allen hex key 2 5mm Additional Inserts and Jet plates o Jet J1 0 3mm thick o Jet J3 0 1mm thick o Insert I2 Optimal configuration see table Socket Optimal Insert Optimal Jet AMD AMx F...

Страница 5: ...ws into four M4 threaded stubs on the LGA 2011 socket integrated latch mechanism ILM The screws are to be installed using no tools i e pliers STEP 5d Preparing your CPU and applying TIM Cleaning the C...

Страница 6: ...air possible You must use the push mode as it eases the fan cable routing First you need to assemble the fan fan holder and the radiator Take the four UNC 6 32 screws for each fan and route them thro...

Страница 7: ...screws as shown on the sketch Make sure all the screws are tight as the vibrations that come from the pump may loosen them Examine the water loop diagram Take a measure of required tubing length Cut...

Страница 8: ...nnect 4 pin Molex female connector to male Molex connector of the power supply Prepare enclosed Y fan splitter cable To connect the fans plug in 3 PIN female fan connectors to male fan splitter cable...

Страница 9: ...ing and stop when the water level reaches 2 cm under the edge Alternately turn off and on cycle power supply in few second intervals to speed up air bleeding process Close the reservoir by screwing in...

Страница 10: ...o the container Let the water run away into the container Keep one tube in the container and gently blow into the other tube to additionally drain the system You may need to tilt the whole case in ord...

Отзывы: