/ 25 /
FILLING UP THE SYSTEM
Before starting to fill the system, you should prepare some paper
towels in case of dripping. In order to fill up successfully please fol-
low the steps below.
STEP 1:
Use the 6mm Allen key (supplied with every EK water block) to
unscrew the plug on the back side of the Phoenix Radiator Core.
STEP 2:
Start filling process by adding coolant through the port on the back
of the unit as shown on the picture on STEP 2. Pour the coolant
slowly until the unit is full, then shake it a bit, to get out as much air
as possible. You can alternatively screw the plug in and rotate the
unit in multiple directions and then repeat the procedure unit until
there is no air left in the unit.
It is essential to get as much air as possible out of the sys-
tem at this stage!
STEP 3:
Reinstall the plug, removed in STEP 1 using the 6mm Allen key. Af-
terwards place the unit on the firm surface with fans facing upwards
as pictured in STEP 3 and 4.
STEP 4:
Unscrew the integrated reservoir plug in counter-clockwise direc-
tion. Add more coolant until the unit seems full.
STEP 1 and 2
STEP 3 and 4