background image

All disclosures, notices and warranty conditions are being written on EKWB website.          

 

 

 

 Revision 1. Released on 5

th

 of Merch 2019 

STEP 4: PREPARING CPU AND APPLYING THERMAL GREASE (TIM)

 

STEP 5: INSTALLING THE WATER BLOCK

 

 

 

 

STEP 6: CONNECTING THE WATER BLOCK TO THE COOLING LOOP

 

 

 

 

 

Cleaning  the  CPU:

  Wipe  the  CPU

’s  contact  surface

  (by  using  non

abrasive cloth or 

Q-tip

). 

 

Applying thermal compound:

 EK recommends a blob or line method 

of applying the enclosed EK-TIM Ectotherm

™ thermal

 compound to the 

CPU  heatspreader  (IHS)  -  see  sample  photo  on  right.  The  quantity  of 

about pea size is just about right. There is no need to cover the whole 

IHS. Applying too much thermal grease will have negative impact on the 

cooling performance! 

 

1) On majority of motherboards the EK-Annihilator Pro ILM can be 
sucessfully installed with motherboard already being pre-fitted to the 
computer chassis. Still, it is best practice to place a motherboard on an 
even surface with front side facing up. 
2) Install CPU and apply TIM (thermal grease) as shown in STEP 5 
3) Align water block above the LGA 3647 socket on motherboard with 
pre-installed CPU. 
4) Tighten the screws using 4mm Allen Key the cross pattern. 

 

5a: Tightening sequence: 

You have to tighten the screws in cross pattern sequence using 4mm 

Allen Key. Screws 1 and 2 must be tightened until they hit the limiter 

and are not able to turn more. 

Do not overtighten the screws 3 and 4! 

 

2

 

3

 

4

 

Step 6a: Connecting G1/8 fittings with tube:  

Carefully identify the direction of the flow in your circuit. EK recommends the 

use of EK-HFB Fitting 6mm G1/8 and EK-Tube ZMT 6/9mm Matte Black tubing.  

1. Install Barb 1/8 [1] to the CPU block by using 3/16 Allen Key. 

2. Mount Clamp [3] to the tubing [2] 

3. Mount the tube [2] to the barb [1] 

 

Step 6b: Connecting G1/4 fittings with tube: 

 

Carefully identify the direction of the flow in your circuit. EK recommends the 
use of EK-HFB 10 mm barb fittings and 

EK-Tube ZMT 10/16mm

.  

 

 

The use of biocide containing and corrosion inhibiting coolant is always 
recommended for any liquid cooling system. EK recommends using EK-CryoFuel.

 

2

 

3

 

Отзывы: