9
Instrument has the indicator for power display, slowing down of mast lifting, parking
and working time display function. when the battery power is too low, the power
meter will cut off the control circuit of pump motor. The forklift cannot raise but only
walk, which means the forklift should be charged immediately.
Oil pump motor is a DC motor with five-minute working system, so pump motor is
not suitable for long continuous operation. The vertical movements should have time
interval, should not be continuous, otherwise it causes the motor to heat, or even
burned.
Special Note: When the forklift is used for a long time, pump motor starter may have
fault. The performance is that the starter cannot pull back or cannot be disconnected.
The latter one is acted as no pulling the multi-way valve control lever, pump motor
will keep turning. The forklift should be stopped immediately, turn off the power
(unplug the battery plug-in), so that the pump motor stops, and timely replacement
starter.
The forklift is equipped with front headlights, rear lights, reversing horn and other
safety and lighting devices
The switch groups
Содержание EK13A
Страница 2: ...2 Contents...
Страница 4: ...4 EK15A...
Страница 26: ...26 Perform balanced recharging to accumulator once a month in normal use...