23
4.4.5 Specification of the accumulator
Battery
Charger
Rated power
:
24V
Rated capacity
:
350Ah
Input
:
AC115/230
50Hz
Output
:
DC24V50A
Uninsulated terminal poles on the accumulator should be protected with an insulated
cover. When connecting the accumulator and socket, make sure to stop the forklift
and put the switch at position “0”.When replace or install the accumulator, make sure
the accumulator is fixed securely in battery box.
4.4.6 Storage, transportation and installation of the accumulator
The forklift must be parked on the level ground steadily. To prevent short circuit,
naked cable ends and the terminal posts should be covered with insulated covers.
When pulling out the accumulator, properly arrange removed accumulator's
connectors and cables without blocking access of the accumulator.
When install or remove the accumulator with a crane, make sure the load
capacity is sufficient (weight of the accumulator is marked on both the nameplates of
the accumulator and the stacker.) The crane must pull vertically to prevent the battery
box from being damaged. The hooks of the crane should be safe and secure. Never let
the hooks fall on an individual battery .
— Press emergency stop switch and turn the power supply switch to OFF
position
— Remove the connectors of accumulator cables.
—Connect the lifting device to lifting holes.
—Lift out the accumulator from the top and move away with handling
equipment.