background image

Important

Please read this “Instructions for Use”, and “Installation Manual” 
(separate volume) carefully to familiarize yourself with safe and 
effective usage.
Please retain this manual for future reference.

 

For monitor adjustment and settings, refer to the “Installation 

Manual”.

 

For the latest product information including the “Instructions for 

Use”, refer to our web site :

   http://www.eizoglobal.com

Color LCD Monitor

Instructions for Use

English

Содержание RadiForce MX194

Страница 1: ...urself with safe and effective usage Please retain this manual for future reference For monitor adjustment and settings refer to the Installation Manual For the latest product information including th...

Страница 2: ...unit This product has been adjusted specifically for use in the region to which it was originally shipped If operated outside this region the product may not perform as stated in the specifications N...

Страница 3: ...n of the Caution Statements Symbols on the unit Symbol This symbol indicates Power button Press to turn the monitor s power on or off Alternating current Alerting electrical hazard CAUTION Refer to SA...

Страница 4: ...not place in any form of transportation ships aircraft trains automobiles etc Do not place in dusty or humid environments Do not place in locations where water may be splashed on the screen bathrooms...

Страница 5: ...and install the unit securely Otherwise the unit may become detached resulting in injury and or equipment damage Before installation make sure that desks walls or any other installation surface has a...

Страница 6: ...tall the unit in a place with poor ventilation or inadequate space Do not use the unit laid down or upside down Blocking the ventilation slots prevents proper airflow and may result in fire electric s...

Страница 7: ...even after a short time period has elapsed depending on the displayed image If this occurs changing the image or leaving the power off for a few hours may solve the problem The backlight of the LCD p...

Страница 8: ...ng change Using the monitor with the control buttons locked is recommended after adjusting the screen of the monitor For details on how to set refer to the Installation Manual on the CD ROM Cleaning P...

Страница 9: ...and Functions 11 Chapter 2 Installation Connection 12 2 1 Before Installing the Product 12 Installation Requirements 12 2 2 Connecting Cables 13 2 3 Turning On the Power 14 2 4 Adjusting the Screen He...

Страница 10: ...l position for easy operation and minimizing fatigue Tilt 30 up 0 down swivel 35 right 35 left adjustable height 100 mm 1 2 Package Contents Check that all of the following items are included in the p...

Страница 11: ...e operation guide and the menus refer to the Installation Manual on the CD ROM 3 button Turns the power on or off 4 Power Indicator Indicates the monitor s operation status Green Operating Orange Powe...

Страница 12: ...this product on a lacquer coated desk the color may adhere to the bottom of the stand due to the composition of the rubber Check the desk surface before use Installation Requirements When installing t...

Страница 13: ...ns page 17 before connecting the PC 1 Connect signal cables Check the shapes of the connectors and connect the cables After connecting the DVI cable or the D Sub cable to the monitor tighten the faste...

Страница 14: ...ompletely when not using the monitor Note When turning on the monitor and PC for the first time with the analog signal the Auto Adjustment function works to adjust the clock phase and display position...

Страница 15: ...r reboot the PC 2 The message below appears This message appears when the signal is not input correctly even when the monitor functions properly This message appears when no signal is input Example Th...

Страница 16: ...400 69 Hz 71 Hz D Sub 50 0 Hz 75 0 Hz Synchronization Signal Separate Dot Clock Max DVI DisplayPort 108 MHz D Sub 135 MHz USB Port Upstream x 1 Standard USB Specification Revision 2 0 Power Input 100...

Страница 17: ...nnected and DP Power Save On 4 2 Compatible Resolutions The monitor supports the following resolutions For Digital Signal Input DisplayPort DVI Resolution Vertical Scan Frequency 640 x 480 60 Hz 720 x...

Страница 18: ...or EIZO FP 702 Arm Stand EIZO LS HM1 D Dual height adjustable stand EIZO LA 011 W Wall hung arm EIZO AAH 02B3W Wall hung arm Calibration Kit EIZO RadiCS UX2 Ver 4 6 3 or later Network QC Management So...

Страница 19: ...etic waves that could influence limit or result in malfunction of the monitor Install the equipment in a controlled environment where such effects are avoided Classification of Equipment Type of prote...

Страница 20: ...ent or stacked use is necessary the equipment or system should be observed to verify normal operation in the configuration in which it will be used When using a portable RF communication equipment kee...

Страница 21: ...idance Electrostatic discharge ESD IEC EN61000 4 2 8 kV contact discharge 15 kV air discharge 8 kV contact discharge 15 kV air discharge Floors should be wood concrete or ceramic tile If floors are co...

Страница 22: ...site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Note 1 UT is the a c mains voltage...

Страница 23: ...aximum power W Minimum separation distance m IEC EN60601 test level V m Compliance level V m 385 380 390 TETRA 400 Pulse modulation b 18 Hz 1 8 0 3 27 27 450 430 470 GMRS 460 FRS 460 FM 5 kHz deviatio...

Страница 24: ...Hz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output po...

Страница 25: ...ce to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television receptio...

Страница 26: ...ZO Corporation All rights reserved 1st Edition March 2018 Printed in Japan 00N0N072A1 IFU MX194 6 http www eizoglobal com 153 Shimokashiwano Hakusan Ishikawa 924 8566 Japan 8 5B Siemensallee 84 76187...