Cleaning, Maintenance and Care
48
Eisfink Max Maier GmbH & Co. KG
8.11
Inspect technical compartment; clean if necessary
WARNING
Rotating parts
. The impeller wheel of the radial fan rotates when the power to the
appliance is switched on.
►
Switch off the electrical power to the appliance and disconnect from the power supply
before opening the technical compartment.
8.11.1 Inspect and clean technical compartment, replace filter
# Notes on opening and closing
Opening angle around 70 to 90 °, simply remove or insert the cover.
# Inspect technical compartments for soiling
The steam and vapour extracted by the radial fans, which contain grease in addition to water vapour,
are also deposited on the surfaces.
Inspect the condition, such as greasy surfaces. Do this by touching several points on the stainless
steel surfaces with your finger and feeling it.
# Note on quick cleaning
Clean the soiled stainless steel surfaces with a
hot cloth slightly dampened
with a
mild
detergent solution. After cleaning, rub the surfaces dry with a
soft cloth
.
# Note on professional cleaning
Remove active carbon filter.
Remove the radial fan if necessary by pulling it out along the guides and place it on a soft surface.
Clean the
surfaces in the technical compartment
with a
hot
,
mild
detergent diluted in water.
After cleaning, rub the surfaces dry with a
soft cloth
.