Before First Use
Eisfink Max Maier GmbH & Co. KG
23
6.2
Observe when commissioning/recommissioning
Preconditions
The appliance has no defects or visible damage.
The appliance is at room temperature and is dry.
Wear safety shoes to prevent injuries.
ATTENTION
Protective foils or heat-sensitive objects at/in the appliance might damage the appliance
during heating.
►
Ensure that there are no protective foils on the inside or outside of the appliance.
Comply with the mechanical installation conditions
The place of installation must be horizontal.
The casters must be secured by 'parking brakes' to prevent accidental running away.
Maintain a minimum distance from walls, to prevent fingers, clothes, etc. from getting caught when
putting food in/taking food out.
Do not use the appliance as a means of transport.
If necessary, adjust the height-adjustable swivel casters
For this, loosen the locking nut with the wrench and adjust the axle.
▌
When turning clockwise, the installation height is reduced.
User tip.
Use a spirit level for lengthwise and transversal adjustment.
Comply with the applicable electrical requirements
Before commissioning, check the mains voltage and type of current.
Check that these match the specifications on the type plate.
Connect this electrical appliance to an outlet with an upstream ground fault circuit interrupter with a
tripping current of 30 mA.
The electrical requirements of VDE 0100 ff. and the technical connection requirements of the local
electricity company must be met.
The socket outlet must be easily accessible so that the unit can be disconnected from power
supply at anytime.