background image

GB

- 12 -

 

 Important!

 When using the equipment, a few safety pre-

cautions must be observed to avoid injuries and 

damage. Please read the complete operating 

instructions and safety regulations with due care. 

Keep this manual in a safe place, so that the in-

formation is available at all times. If you give the 

equipment to any other person, hand over these 

operating instructions and safety regulations as 

well. We cannot accept any liability for damage 

or accidents which arise due to a failure to follow 

these instructions and the safety instructions.

1. Safety regulations

  Caution!

Read all safety regulations and instructions.

Any errors made in following the safety regula-

tions and instructions may result in an electric 

shock, 

fi

 re and/or serious injury.

Keep all safety regulations and instructions 

in a safe place for future use.

 This appliance is not intended for use by persons 

(including children) with reduced physical, sen-

sory or mental capabilities, or lack of experience 

and knowledge, unless they have been given 

supervision or instruction concerning use of the 

appliance by a person responsible for their safety. 

Children should be supervised to ensure that they 

do not play with the appliance.

 Important! The following basic safety 

actions must be taken when using this com-

pressor in order to protect the user from 

electric shocks and the risk of injury and 

fi

 re. 

Read and follow these instructions before 

using the equipment.

• 

 Keep your work area tidy 

Untidy work areas can result in accidents.

• 

 

Check the ambient conditions 

Do not expose the compressor to rain. Never 

use the compressor in damp or wet locations. 

There is a risk of electric shock!  Provide 

good lighting. Do not use the compressor 

near flammable liquids or gases. There is a 

risk of explosion!

• 

 Protect yourself against electric shocks 

Avoid bodily contact with earthed parts, e.g. 

pipes, radiators, cookers and refrigerators.

• 

 Keep children away! 

Do not allow other persons to touch the com-

pressor or cable, keep them away from your 

work area.

• 

 

Keep your compressor in a safe place

When unused, the compressor must be 

stored in a dry, locked room out of children’s 

reach.

• 

 Do not overload your compressor 

 

It will run better and safer within its quoted 

capacity range.

• 

 Wear suitable work clothes 

Never wear loose fitting clothes or jewellery. 

They may get caught in moving parts. Rubber 

gloves and non-slip shoes are recommended 

when working outdoors. Wear a hair net if you 

have long hair. Risk of injury! 

• 

 Do not use the cable for purposes other 

than that for which it is designed  

Do not carry the compressor by its cable and 

do not use the cable to pull the plug out of the 

socket. Protect the cable from heat, oil and 

sharp edges. The cable/plug could become 

damaged.

• 

 

Take care of your compressor 

Keep your compressor clean in order to work 

well and safely. Follow the maintenance inst-

ructions. Check the power plug and cable on 

a regular basis and have them replaced by 

an authorized specialist if they are damaged. 

Check the extension cable regularly and re-

place it if damaged.

• 

 Pull out the power plug 

When not in use and before carrying out any 

maintenance work.

• 

 

Avoid unintentional starting 

Make sure that the switch is turned off when 

connecting to the power supply.

• 

 When using an extension cable outdoors  

Check that it is approved for outdoor duty and 

is marked accordingly.

• 

 Be alert at all times 

Watch what you are doing. Use common sen-

se when working. Never use the compressor 

when you are distracted.

• 

 

Check your compressor for damage 

Before using the compressor again, carefully 

check the safety devices and any slightly da-

maged parts to ensure that they are in good 

working order. Check that the moving parts 

are working correctly, that they do not jam, 

and that no parts are damaged. Make sure 

that all parts are fitted correctly to ensure that 

the equipment remains safe to use. Unless 

otherwise stated in the operating instruc-

tions, damaged guards and parts have to be 

Anl_SA_TH_AC_190_Kit_SPK8.indb   12

Anl_SA_TH_AC_190_Kit_SPK8.indb   12

03.05.16   10:50

03.05.16   10:50

Содержание TH-AC 190 Kit

Страница 1: ...0 Kit 8 E Manual de instrucciones original Compresor GB Original operating instructions Compressor South America Anl_SA_TH_AC_190_Kit_SPK8 indb 1 Anl_SA_TH_AC_190_Kit_SPK8 indb 1 03 05 16 10 50 03 05...

Страница 2: ...2 1 4 5 1 3 2 2 3 e c a 6 b 2 6 d Anl_SA_TH_AC_190_Kit_SPK8 indb 2 Anl_SA_TH_AC_190_Kit_SPK8 indb 2 03 05 16 10 50 03 05 16 10 50...

Страница 3: ...er en marcha sin necesidad de aviso Usar protecci n para los o dos La exposici n al ruido puede ser perjudicial para el o do Aviso Leer el manual de instrucciones para reducir cualquier riesgo de sufr...

Страница 4: ...o est bien iluminada No utilizar el compresor cerca de l quidos o gases inflamables Peligro de explosi n Protegerse contra descargas el ctricas Evitar el contacto corporal con cualquier tipo de piezas...

Страница 5: ...que el com presor pueda disfrutar de la mayor presi n de trabajo admisible Lugar de instalaci n Colocar el compresor solo en una superficie uniforme Instrucciones de seguridad para trabajar con aire...

Страница 6: ...el aparato Retirar el material de embalaje as como los dispositivos de seguridad del embalaje y para el transporte si existen Comprobar que el volumen de entrega est completo Comprobar que el aparato...

Страница 7: ...e construcci n y no su pone que haya una aver a 6 Montaje y puesta en servicio Atenci n Montar completamente el aparato antes de ponerlo en servicio 6 1 Conexi n a la red Antes de la puesta en marcha...

Страница 8: ...ventilaci n y la carcasa del motor Frotar el aparato con un pa o limpio o soplarlo con aire comprimido manteniendo la presi n baja Se recomienda limpiar el aparato tras cada uso Limpiar el aparato con...

Страница 9: ...accesorios est n compuestos de diversos materiales como p ej metal y pl stico Los aparatos defectuosos no deben tirarse a la basura dom stica Para su eliminaci n adecu ada el aparato debe entregarse...

Страница 10: ...ausa del sobrecalentamiento El compresor est en marcha pero no hay presi n 1 La v lvula de retenci n presenta fugas 2 Las juntas est n rotas 1 Cambiar la v lvula de retenci n en un taller especializad...

Страница 11: ...remote controlled and may start up without warning Wear ear mu s The impact of noise can cause damage to hearing Caution Read the operating instructions to reduce the risk of inquiry Anl_SA_TH_AC_190_...

Страница 12: ...low other persons to touch the com pressor or cable keep them away from your work area Keep your compressor in a safe place When unused the compressor must be stored in a dry locked room out of childr...

Страница 13: ...unding hose Wear safety goggles when working with the blow out pistol Foreign bodies or blown off parts can easily cause injuries Do not blow at people with the blow out pistol and do not clean clothe...

Страница 14: ...if the machine is used in commercial trade or industrial businesses or for equivalent purposes 4 Technical data See warranty card of your country Noise The noise emission values were measured in ac co...

Страница 15: ...se 6 4 Tire pressure gauge with adapters Fig 2 Item 6 Working pressure in bar 0 8 0 0 8 MPa Range of applications The tire pressure gauge allows you to inflate tires easily and exactly Use the pressur...

Страница 16: ...the mains plug out of the socket and ventilate the appliance and all connected pneumatic tools Switch o the compressor and make sure that it is secured in such a way that it cannot be started up agai...

Страница 17: ...ssary remedy the cause of the overheating The compressor starts but there is no pressure 1 The non return valve leaks 2 The seals are damaged 1 Have a service center replace the non return valve 2 Che...

Страница 18: ...re da os ocasionados al acabado del gabinete roturas golpes rayaduras etc como as tam poco las bater as ni los da os ocasionados por deficiencias o interrupciones que afecten el circuito el ctrico de...

Страница 19: ...Argentina S A respecto del comprador o de cualquier otra parte como eventual consecuencia de un reclamo fundado en contrato o en obligaciones extracontractuales podr exceder un monto total equivalente...

Страница 20: ...ca l min 190 Potencia generada aire comprimido a 7 bar 0 7 MPa 55 l min Potencia generada aire comprimido a 4 bar 0 4 MPa 83 l min Nivel de potencia ac stica LWA en dB 97 Imprecisi n KWA 1 5 dB Nivel...

Страница 21: ...d introducci n de cuerpos extra os en el aparato como p ej arena piedras o polvo uso violento o influencias externa como p ej da os por ca das as como por el desgaste habitu al por el uso Esto se apli...

Страница 22: ...ca l min 190 Potencia generada aire comprimido a 7 bar 0 7 MPa 55 l min Potencia generada aire comprimido a 4 bar 0 4 MPa 83 l min Nivel de potencia ac stica LWA en dB 97 Imprecisi n KWA 1 5 dB Nivel...

Страница 23: ...a podemos coordinar su reparaci n Para este caso es importante tener presente las siguientes recomendaciones Aseg rese de enviar el equipo sin accesorios Dentro de la caja para su env o anexe copia de...

Страница 24: ...ca l min 190 Potencia generada aire comprimido a 7 bar 0 7 MPa 55 l min Potencia generada aire comprimido a 4 bar 0 4 MPa 83 l min Nivel de potencia ac stica LWA en dB 97 Imprecisi n KWA 1 5 dB Nivel...

Страница 25: ...caso fortuito y los ocasionados por mudanzas o traslados Para averiguar el servicio t cnico de Einhell autorizado m s pr ximo comun quese al 01 319 0660 extensi n 650 o al e mail servicio clientes ar...

Страница 26: ...ador o de cualquier otra parte como eventual consecuencia de un reclamo fundado en contrato o en obligaciones extracontractuales podr exceder un monto total equivalente al precio de compra del product...

Страница 27: ...ca l min 190 Potencia generada aire comprimido a 7 bar 0 7 MPa 55 l min Potencia generada aire comprimido a 4 bar 0 4 MPa 83 l min Nivel de potencia ac stica LWA en dB 97 Imprecisi n KWA 1 5 dB Nivel...

Страница 28: ...EH 04 2016 01 Anl_SA_TH_AC_190_Kit_SPK8 indb 28 Anl_SA_TH_AC_190_Kit_SPK8 indb 28 03 05 16 10 50 03 05 16 10 50...

Отзывы: