It is recommended that the condensate be
drained off to a drain which is at a lower level. If
you use an external collecting container (e.g. a
trough), the appliance must be positioned at a
higher level accordingly.
The drainage hose must be fitted with a gradient.
Do not kink the hose or allow it to become
clogged.
7. Cleaning, maintenance and ordering
of spare parts
Always pull out the mains power plug before starting
any cleaning work.
Cleaning the air filter (Fig. 10)
The equipment is fitted with a dust filter. This should
be cleaned at least once a month dependant on the
operating conditions.
Important:
Never use the equipment without air
filters.
Remove the condensate collector. Then pull the filter
forward out of the housing. Use a vacuum cleaner or
tap the dust filter gently to remove the dust. If the
filter is very dirty, wash it carefully with warm water
(max. 40°C). Never expose the filter to the sun or
any other sources of heat. Never fit the filter back in
the equipment while still damp.
Cleaning
Clean the equipment regularly with a moist cloth
and some soft soap. Do not use cleaning agents or
solvents; these could attack the plastic parts of the
equipment. Ensure that no water can seep into the
device.
Storage
If you do not intend to use the dehumidifier for a long
period, do the following:
Switch off the unit, pull out the power plug and
reel up the power cable.
Empty the water tank and carefully dry it.
Clean the ventilation grille, place a cover over
the unit and store it where there is little sunlight.
Maintenance
There are no parts inside the equipment which
require additional maintenance.
Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
8. Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
9. Troubleshooting
The unit fails to start:
- Check whether the power plug is correctly
inserted.
- Check whether there is any electricity.
- Is there a power failure?
- Is the lamp on the water level indictor shining?
If it is, either the tank is full and must first be
emptied or the tank is not correctly inserted.
The unit seems to be having no effect:
- Is the filter dirty or contaminated?
- Is the air inlet or outlet blocked?
- Is the humidity in the room already very low?
The unit seems to be having very little effect:
- Are too many doors and windows open?
- Is there anything in the room which is creating
a great deal of humidity?
The unit is very loud:
- Is the unit standing insecurely or at any angle,
resulting in vibrations?
- Is the floor uneven?
Important! Never attempt to repair the device
yourself. Always seek the assistance of your
customer services dealer.
GB
13
Anleitung_LEF_10_SPK7:_ 12.09.2007 15:51 Uhr Seite 13
Содержание LEF 10
Страница 2: ...1 2 3 2 1 6 7 3 4 5 8 9 10 11 12 13 2 Anleitung_LEF_10_SPK7 _ 12 09 2007 15 51 Uhr Seite 2...
Страница 3: ...4 5 7 8 6 MAX OFF A 6 B 2 1 5 3 4 3 Anleitung_LEF_10_SPK7 _ 12 09 2007 15 51 Uhr Seite 3...
Страница 4: ...9 10 4 Anleitung_LEF_10_SPK7 _ 12 09 2007 15 51 Uhr Seite 4...
Страница 34: ...34 Anleitung_LEF_10_SPK7 _ 12 09 2007 15 52 Uhr Seite 34...