Services
Trouble Shooting
13
Services
Trouble Shooting
Problem
Causes
Solutions
No Display / Not
switched on
No power to fixture
Check AC mains power and connections
Inspect connections and cables. Correct poor
connections. Repair or replace damaged cables
Check the power supply voltage.
Fixture does not
respond to DMX
correctly.
Incorrect fixture DMX addressing
Check the fixture is assign to correct DMX address
(See Page 9)
Incorrect DMX mode
Check fixture is set to correct DMX mode (See Page
11)
Fault on data link
check for the data link is correctly linked from the
DMX source if all cables are in good condition
Other device on DMX link
defective.
Unplug eventCON® IN and OUT connectors and
connect them directly together to bypass one
fixture at a time until normal operation is regained
Data transmission lines should
be terminated.
Insert termination plug in OUTPUT of the last fixture
on the link.
LC-Display works
but no light outputs
can be generated.
Faulty DMX link
Run built-in test mode or static control mode to
verify if LEDs are illuminated
Broken parts / wires / LEDs
Have fixtures serviced by an Ehrgeiz service
technician
Maintenance
There are no serviceable Part inside your BabyBeam 4. If problems occur,
contact your Ehrgeiz dealer or a qualified Ehrgeiz Service technician.
Use a slightly moist and smooth cloth to clean the device. Do not use any
aggressive detergents.
We are sure you will have a sophisticated experience with your BabyBeam 4.