background image

 
 

 

Introduction 

  Safety Instructions 

 

Introduction 

Thank you for your purchase and usage of the Ehrgeiz BabyBeam 4. 
You have chosen a reliable product with outstanding features like the unique 
eventCON® connector system or the Tilt Index. The device is easy to use and 
is made of high quality components. 
Every Ehrgeiz Product is checked before shipping to secure you are able to 

receive a great product without compromise. This is not a toy. Our ambitious 
aim is to get you a reliable working tool. 

Safety Instructions 

In General 

In order to maintain the condition and to ensure a safe operation, it is 
important for all users to follow the safety instructions and warning notes 

written in this manual. 
Do not operate the fixture with missing or damaged covers, shields or any 
optical component. 
Please consider that unauthorized modifications to the device are forbidden 
due to safety reasons.  

If the device is operated in any way that’s not described in this manual, the 

product may suffer damage and the guarantee will become void. 
Furthermore, misuse may lead to dangers like short-circuit, burns, electric 
shock, burns due to ultraviolet radiation, lamp explosion, crash, etc. 

IP67 protection rating 

The fixture is protected against dust (first digit 6) and against Immersion, up 
to 1m depth tested for 30 minutes (second digit 7). 

Prevention from electrical shock 

Make sure to ground (earth) the fixture electrically. (It’s essential to connect 

the yellow/green conductor to earth) 

Main Connection 

Do not apply any AC mains power to the fixture at any other voltage than 
that specified.  
Never let the eventCON® cable come into contact with other cables. Treat the 

eventCON® cable and all connections with the mains with particular caution. 
Make sure the eventCON® cable is never crimped or damaged by sharp 
edges. 

Rigging 

Check that all external covers and rigging hardware are securely fastened. 
When choosing the installation-location, please make sure that the fixture is 
not exposed to extreme heat. There should not be any cables lying around. 

You endanger your own and the safety of others. 

Содержание BABYBEAM4

Страница 1: ...Manual released for Software Version 2 0 0 3 from 02 06 2017 This Manual is released on 2 21 2017 USER MANUAL...

Страница 2: ...anging 4 Safety attachment 4 Omega Bracket 5 Connections 6 Mains DMX 6 DMX 7 Operations 8 Menu control 8 Menu map 9 Software updates 11 DMX Modes 11 std 8 Standard Mode 11 tl1 5 Mode 12 tl2 6 Mode 12...

Страница 3: ...described in this manual the product may suffer damage and the guarantee will become void Furthermore misuse may lead to dangers like short circuit burns electric shock burns due to ultraviolet radia...

Страница 4: ...approved by an official body The safety wire must comply with EN 60598 2 17 Section 17 6 6 and be capable of bearing a static suspended load ten times the weight of the fixture Positioning The fixture...

Страница 5: ...4 with the following content BabyBeam 4 4x15W Osram LED Beamlight with 8 beam angle eventCON Input cable Input cable with Neutrik XLR and Schuko merging to Eventcon Diffusor kit 18 58 Filters Diffuso...

Страница 6: ...fe operation and secure handling Installation on the floor You could place the BabyBeam 4 on the floor Please make sure the surface is plane and the reliability of the floor is sufficient Installation...

Страница 7: ...Installations Omega Bracket 5 Omega Bracket There are optional Omega Bracket fittings available for your BabyBeam 4 Attach them with the screws onto the suspension...

Страница 8: ...connection of the Power supply has to be done by qualified personnel only Do not connect the BabyBeam 4 if you are not able to survey the consequences Do not try to connect another Type of Plug than a...

Страница 9: ...Please notice that the USITT DMX Standard does allow the use a max of 32 DMX fixtures in one line You should terminate the signal by a 120 resistor In the Standard mode the BabyBeam 4 uses 8 DMX chann...

Страница 10: ...Menu of the BabyBeam 4 is mainly intuitive You will find a menu map on the following pages The four buttons are used to scroll the values select a setting or hop back in the menu structure Menu Go bac...

Страница 11: ...in case of signal loss prog1 play prog 1 in case of signal loss sound1 play prog 1 sound triggered in case of signal loss prog2 play prog 2 in case of signal loss sound2 play prog 2 sound triggered i...

Страница 12: ...step01 Capt capture and save the actual DMX input Skip abort editing of this step red 0 255 change the value for red green 0 255 change the value for green blue 0 255 change the value for blue white 0...

Страница 13: ...n set up your BabyBeam 4 in 6 different DMX Modes std 8 Standard Mode Page11 Uses 8 DMX channels tl1 5 Mode Page 12 Uses 5 DMX channels tl2 6 Mode Page 12 Uses 6 DMX channels RGBW 4 Mode Page 12 Uses...

Страница 14: ...CH Function 1 Dimmer 2 Red 3 Green 4 Blue 5 White 6 Shutter see Shutter effects chart Appendix Page VII RGBW 4 Mode CH Function 1 Red 2 Green 3 Blue 4 White RGB 3 Mode CH Function 1 Red 2 Green 3 Blue...

Страница 15: ...on DMX link defective Unplug eventCON IN and OUT connectors and connect them directly together to bypass one fixture at a time until normal operation is regained Data transmission lines should be term...

Страница 16: ...Services Maintenance 14...

Страница 17: ...nternal noiseless fan Control and programming Setting Addressing 1x6 characters LED display 4 buttons Protocol USITT DMX 512 Control channels 2 3 4 5 6 8 6 DMX protocol modes 3 editable programs each...

Страница 18: ...Appendix Exploded drawing II Exploded drawing...

Страница 19: ...g Rubber for Input Button 1 106267 15 Water sealing O ring 1 106266 16 Top Water sealing O Ring 1 1 106254 17 Bottom Water sealing O Ring 1 106265 20 Power Isolation Mylar 1 114440 21 Power Supply Uni...

Страница 20: ...the event industry In order that the eventCON system works with your classic fixtures we have developed adapter sets which connect classic XLR Schuko PowerCON with the eventCON system Technial Data Co...

Страница 21: ...Appendix eventCON V Here is an extract of the available eventCON accessories...

Страница 22: ...Blue Green 101 105 LEE 124 Dark Green 106 110 LEE 139 Primary Green 111 115 LEE 089 Moss Green 116 120 LEE 122 Fern Green 121 125 LEE 738 JAS Green 126 130 LEE 088 Lime Green 131 135 LEE 100 Spring Ye...

Страница 23: ...5 Shutter Closed 16 47 Random Strobe slow fast 48 79 Ramp Up slow fast 80 111 Ramp Down slow fast 112 143 Ramp UP down slow fast 144 199 Strobe Pause 5s 1s slow fast 200 239 Strobe 1Hz 20 Hz slow fast...

Страница 24: ...Ehrgeiz Lichttechnik GmbH Im St ckm dle 2 D 76307 Karlsbad Germany Tel 49 7248 947 90 10 Fax 49 7248 947 90 12 Web www ehrgeiz com...

Отзывы: