3. Before the installation

Conditioning the boards

Before starting the installation, the packs of laminate and Comfort flooring should be stored / acclimatised in the room where they 
are going to be installed or in a room with an equivalent climate. Acclimatisation takes place in the following conditions:

 

ƒ

The flooring is in its packaging

 

ƒ

It is stored / acclimatised for a period of at least 48 hours

 

ƒ

It is laid flat with a minimum of 50 cm distance from all walls

 

ƒ

The room temperature is at least 18° C

 

ƒ

The surface temperature of the floor is at least 15° C

 

ƒ

The relative atmospheric humidity is between 40 % and 70 %.

Direction of installation

Laminate and Comfort flooring looks best when the panels are installed parallel to the light coming in through the windows. 
However, there are binding requirements for the direction of installation for sub-floors made of board flooring, or strip 
parquet / wooden floors on ships. In those cases, installation must be done at right angles to the boarding or the direction of the 
strip parquet / wooden floor. 

Planning the first row

First, the room must be measured to determine whether the width of the first row should be reduced. This is always necessary if the 
last row being installed works out to be narrower than 5 cm.

Attention!

 The flooring elements (floor boards) must be cut lengthways from the tongue side (red inlay). 

Planning expansion gaps

EGGER Laminate and Comfort flooring are subject – like all organic materials – to a certain movement behaviour 
(shrinking / swelling) due to the changing indoor climatic conditions. Movement of the finished, installed floor is not affected if 
allowance is made with sufficiently dimensioned expansion joints to all fixed objects. 
Expansion gaps 8 to 10 mm wide should be left around all fixed objects such as walls, door frames, pipes, pillars, stairs etc.

Planning movement profiles

Due to the movement behaviour of laminate and Comfort flooring, movement profiles must always be installed in the following 
applications and areas:

 

ƒ

Door thresholds

 

ƒ

Passageways

 

ƒ

Angled areas

 

ƒ

Room lengths and / or widths of more than 10 m

Before the installation 

Содержание UNIfit!

Страница 1: ...Installation instructions for Egger Laminate and Comfort flooring with UNIfit installation system...

Страница 2: ...M For calcium sulphate screeds calcium sulphate floating screeds 0 5CM heated screeds 0 3CM These values apply to screeds without additives With the use of additives and in case of fast setting screed...

Страница 3: ...heating engineer installer floor covering manufacturer must work together in a coordinated manner All surface heated flooring requires appropriate planning and coordination of the heating system and s...

Страница 4: ...nate flooring and Comfort flooring elements are installed at right angles to the floorboards Elastic flooring surfaces PVC linoleum vinyl The use of flexible floor coverings meets the damp proofing re...

Страница 5: ...one at right angles to the boarding or the direction of the strip parquet wooden floor Planning the first row First the room must be measured to determine whether the width of the first row should be...

Страница 6: ...sides of both elements push against each other and fits perfectly Once again lock the longitudinal connection by lowering and at the same time the frontal connection by pushing until you can feel the...

Страница 7: ...leftover piece of the previous row if this is at least 200mm long or 500mm for Long format floor boards You can continue to install board after board now In order to prepare the last row of boards for...

Страница 8: ...and tapping block Figure 1b 1c On door frames that cannot be shortened e g made of metal the fitted expansion joint must be sealed or covered with an elastic jointing material or suitable end profile...

Страница 9: ...ort flooring immediately Steam cleaners should not be used the exception being on Aqua Laminate Flooring Only clean laminate and Comfort flooring with a damp cloth Never use scouring or abrasive mater...

Страница 10: ...3841 301 20222 flooring egger com EGGER Drevprodukt Gagarin Ezhvinsky proezd 1 215010 Gagarin Oblast Smolensk Russia T 7 48135 79 300 F 7 48135 79 311 info ru egger com EN_EGGER_flo_installation_inst...

Отзывы: