PF321A6012
- 11 -
6 Setting the Basic Functions
6.1 Direction of motor rotation
Function
with
or
without
control panel
Parameter
Direction of motor rotation
(drE)
161
161 = 0
Clockwise motor rotation (look at the motor shaft)
161 = 1
Counterclockwise motor rotation
A
TTENTION
If the motor is mounted differently, e. g. at a different angle or with gear, make sure that the
value set using parameter 161 corresponds to the direction of rotation.
6.2 Use of a HSM001 Hall Sensor Module or IPG... Pulse Encoder
Representation and installation of a HSM001 Hall sensor module or IPG... pulse encoder !
Representation and installation of a HSM001 Hall sensor module or PG... pulse encoder together with a
LSM002 light barrier module by means of adapter cord no. 1113229 !
Operation with HSM001 Hall sensor module
Operation with IPG... pulse encoder
-
Get machine to the needle-up position.
-
Position bore for magnet such that the magnet is located
approx. 15° after the sensor in the sense of rotation.
Kl2524b
ca. 15°-30°
approx. 15°-30°
env. 15°-30°
-
Get machine to the needle-up position.
-
Turn disk in the pulse encoder such that the leading edge
will be located approx. 15° after the sensor on the board
in the sense of rotation.
Содержание DC 1550