Instruction Manual
- 10 -
Functions
Parameter
Call-up of the Fast Installation Routine SIR
(Sir)
500
Setting on the V810 control panel:
Input code number
3112
!
Press the
E
key
the lowest parameter
2.0.0.
of this level appears
select
500
Parameter
5.0.0.
displayed
Press the
E
key
the character
[o]
appears and flashes
Press the >> key
Parameter
2.9.0.
appears
(functional sequence "thread trimming
operations")
Press the
E
key
Parameter value
05
appears
Press the
+/-
key
The parameter value can be changed
Press the
E
key
Parameter
1.6.1.
appears
(Direction of motor rotation)
Press the
E
key
Parameter value
1
appears
Press the
+/-
key
The parameter value can be changed
Press the
E
key
Parameter
2.7.2.
appears
(transmission ratio)
Press the
E
key
Parameter value
100
appears
Press the
+/-
key
The parameter value can be changed
Press the
E
key
Parameter
2.7.0.
appears
(type of position sensor)
Press the
E
key
Parameter value
0
appears
Press the
+/-
key
The parameter value can be changed
Press the
E
key
Parameter
4.5.1.
appears
(position 1 leading edge, position 1 trailing edge
is automatically set at 60°)
Press the
E
key
Parameter value appears
Press the
+/-
key
The parameter value can be changed
or turn handwheel
Set position for at least 1 rotation.
Press the
E
key
Parameter
4.5.3.
appears
(position 2 leading edge, position 2 trailing edge
is automatically set at 60°)
Press the
E
key
Parameter value appears
Press the
+/-
key
The parameter value can be changed
or turn handwheel
Set position for at least 1 rotation.
Upon pressing the
E
key once more the program returns to parameter 290!
Press the
P
key twice
The system exits the SIR routine
Setting on the V820/V850 control panel:
Input code number
3112
!
Press the
E
key
the lowest parameter
2.0.0.
of this level appears
select
500
Parameter
5.0.0.
displayed
Press the
E
key
the character
[o]
appears and flashes
Press the
>>
key
Parameter
290 FAm 05
appears
(functional sequence "thread trimming
operations")
Press the
+/-
key
The parameter value can be changed
Press the
E
key
Parameter
161 drE 1
appears
(Direction of motor rotation)
Press the
+/-
key
The parameter value can be changed
Press the
E
key
Parameter
272 trr 100
appears
(transmission ratio)
Press the
+/-
key
The parameter value can be changed
Press the
E
key
Parameter
270 PGm 0
appears
(type of position sensor)
Press the
+/-
key
The parameter value can be changed
Press the
E
key
Parameter
451
appears
(position 1 leading edge, position 1 trailing edge is
automatically set at 60°)
Press the
+/-
key
The parameter value can be changed.
or turn handwheel
Set position for at least 1 rotation.
Press the
E
key
Parameter
453
appears
(position 2 leading edge, position 2 trailing edge is
automatically set at 60°)
Press the
+/-
key
The parameter value can be changed
or turn handwheel
Set position for at least 1 rotation.
Upon pressing the
E
key once more the program returns to parameter 290!
Press the
P
key twice
The system exits the SIR routine