EFKA AB286A5400
24
12 Examples for Serial Data Transfer
12.1 Power On
Before power on, ensure that the right baud rate has been selected by jumpers in the plug. After power on and/or restart, the
control needs approx. 2 seconds to be ready for operation. This status is signalled by
bit 5 in status byte 1
.
Group
No.
Description
Bit
7
6
5
4
3
2
1
0
0
02
Status Byte 1
PSYN
NPE
RDY
P01
P02
POE
DZE
STP
Example:
Query for readiness for operation after power on (RTS parameter 2)
Master transmits
SOH
ADR
STX
($30 $32)
ENQ
Slave transmits
SOH
ADR
STX
($30 $32 $3D $xx $xx))
ETX
BCC
The master recognizes the readiness for operation from bit 5.
12.2 Operation
Example
:
Sequence of the speed profile belo w.
* = Step
Step 1
Determine speed 1 = 4000 [RPM]
Control value A Parameter 10 = 2000 [2 RPM]
Master
SOH
ADR
STX
($31 $30 $3D $37 $44 $30)
ETX
BCC
Slave
ADR
ACK
6/ 7
n
-
CCW
*
n
3
1/ 2
*
4/ 5
*
*
4000
CW
1800
4000
0274- B02
12/ 13
8- 11
*
*
1500
POS.1
POS.2
Содержание AB286A5400
Страница 2: ......