Group 7
System Values C
Parameter 70
- P-divisor
Dividing factor P-controller for adapting the running behavior to the
machine
Parameter 71
- I-divisor
Dividing factor I-controller for adapting the running bahavior to the
machine
Parameter 72
- Stop segment
Number of increments before stop position
Group E
System Values D
Parameter E0
- Actual counter
The actual counter reading of the position transmitter can be read out.
reading
After a reset synchronization is necessary. Use command “go to
reference
point“. Without synchronization a false value will be issued.
Parameter E1
- Actual speed
The actual speed can be read out. It is issued at 2/min. The value must
thus be multiplied by 2.
Parameter E2
- Run-out stop segment
Number of increments after stop position.
Parameter E3
- Communication
Timeout beween the transfers. If the preset time is exceeded, the drive
monitoring
stops in position 2 and sets bit 6 in the communication byte
(0 = funktion disabled).
Group F
Characteristics
Parameter F0
- Entry 1
2 bytes as for ex. serial number can be entered here
Parameter F1
- Entry 2
2 bytes as for ex. workplace number can be entered here
Parameter F2
- Operating hours
2-byte operating hours.
Parameter F3
- Entry 3
2 bytes as for ex. repair note can be entered h ere
Parameter FA
- P.c.b. no.
Main board number
Parameter FB
- Control box no.
Control box number
Parameter FC
- Efka type
Type number with state of development
Parameter FD
- Efka date code
ID code
Parameter FE
- Software version
Program number with modification index
Parameter FF
- Address
The address of the AB286A control is filed here (preset = F0)
8.1 Special Features
When setting the speeds (parameters 10, 11, 61, 62, 63 and 64), half the value must be transmitted, i.e. the value “2000”
[2 RPM] must be transmitted for a requested speed of 4000 [RPM].
8.2 Bit Descriptions
8.2.1
“RDY“ Bit 5 in Status Byte 1
The “ready bit“ will not be set in case of the following errors:
0 = Error, as described below / 1 = Ready for operation
§
Hardware error
§
Software error
§
Position transmitter not connected or defective
§
Commutation transmitter cord or frequency converter disturbed
§
Line voltage too low
§
Blocking, motor overstrained