background image

 

Double row LED bar         

 

USER’S GUIDE EFFI

-SMART 

Version 2.1.2020

 

Last update:

 June 17, 2020

 

 

 

 
 

 

Mini Parc du Verger 

 Bâtiment E 

1 Rue de Terre Neuve 

91940 LES ULIS, FRANCE

 

Tel: +33 9 72 38 17 80 

Fax: +33 9 72 11 21 69 

Email: [email protected]

 

 

Page 2 / 4

 

      

 

 

 

 

EFFI-SMART 

-WW 

-XXX 

-YY 

-ZZ 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of LED 

Wavelength (nm) 

Windows 

Lens position 

Option 

 

12 
36 

 

405 
465 
525 
625 
850 

000 

(White)

 

TR 

(Transparent) 

SD 

(Semi-diffusive)

 

OP 

(Opaline)

 

P0 

(no lens) 

P1 

(45°)

 

P2 

(25°)

 

P3 

(10°)

 

LS 

(linescan) 

POL 

(polarizer)

 

 

 

Regardless of maintenance, the product must be switch off. 

The product is ESD sensitive. Should you open it, take care about ESD matters (use a conductive wrist strap attached to a good

 

 earth ground, use an approved anti-static mat to cover your work surface).   

CHANGE OPTICAL CONFIGURATION

  

 

 

 

(Scheme: P1 configuration)

 

To handle the optical components, wearing gloves is strongly recommended. 
To clean the optical components: Use compressed air duster if there is dust.  
To remove marks on the lens or the window, just a drop or two wiped of alcohol-based lens cleaning fluid in a gentle circular motion with a cleaning 
tissue. Always apply the fluid to a tissue rather than to the lens itself.

 

 

 

 

P0 : Without lens

 

 

 

P1 : screw + 2* lens

 

 

 

P2 : screw +  lens + 

spacer

 

 

 

P3 : screw + lens + 2*spacer

 

Reference  

Maintenance 

Take out the plastic cover

 

Take out the 2 spacers

 

Screw  

2 Spacers 

Lens 

Torx Screwdriver 

Size : T6 

Unscrew the screws on the block of lenses

 

 

Replace the lenses in the right position

 

 

Screw the block of lenses & the cover  

0.2 N.m

 

 

Unscrew the screws

 

 

Option 

  

Содержание Effi-Smart Series

Страница 1: ...any contact with the LED or with the projection lens IP67 Classification Do not immerse the product more than 1 meter in depth Use the device in an environment at 0 C to 45 C with no excessive moistur...

Страница 2: ...an approved anti static mat to cover your work surface CHANGE OPTICAL CONFIGURATION Scheme P1 configuration To handle the optical components wearing gloves is strongly recommended To clean the optica...

Страница 3: ...robe 1 Strobe control triggered on falling edge See DIMMING CONTROL Scheme Not connected 0V Not connected 0V Dimming LED OFF 0V 3V ON 3V 20 10V 100 ON 10 24V 100 3Vdc max 24Vdc 3Vdc max 24Vdc 3Vdc max...

Страница 4: ...update June 17 2020 Mini Parc du Verger B timent E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 38 17 80 Fax 33 9 72 11 21 69 Email contact effilux fr Page 4 4 DIMENSIONS in mm 6 LED 12 LED...

Страница 5: ...ED et avec la lentille de projection Code IP67 Ne pas immerge le produit plus d un m tre de profondeur Utiliser le produit dans un environnement dont la temp rature de travail est situ e entre 0 C et...

Страница 6: ...r la partie plastique 2 Retirer les 2 spacers 4 Vis 2 Spacers Lentille Tournevis Torx Taille T6 D visser les vis du bloc lentille 3 Replacer les l ments dans la bonne configuration 5 Visser les vis du...

Страница 7: ...escendant Voir sch ma contr le DIM Non connect 2 Non connect 2 Cont le DIM LED OFF 0V 3V ON 3V 20 10V 100 ON 10 24V 100 3Vdc max 24Vdc 3Vdc max 24Vdc 3Vdc max 24Vdc Mode Test Les LEDs sont aliment es...

Страница 8: ...17 juin 2020 Mini Parc du Verger B timent E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 38 17 80 Fax 33 9 72 11 21 69 Email contact effilux fr Page 4 4 DIMENSIONS in mm 6 LED 12 LED 36 LED...

Отзывы: