background image

 

Double row LED bar         

 

USER’S GUIDE EFFI

-SMART 

Version 2.1.2020

 

Last update:

 June 17, 2020

 

 

 

 
 

 

Mini Parc du Verger 

 Bâtiment E 

1 Rue de Terre Neuve 

91940 LES ULIS, FRANCE

 

Tel: +33 9 72 38 17 80 

Fax: +33 9 72 11 21 69 

Email: [email protected]

 

 

Page 1 / 4

 

      

 

 

           

 

 

 

 

 

 

VERSION : 

  6 LED

 

  12 LED

 

  36 LED

 

 

Please take a while to consider and read this brochure before using your new device. 

If you have any doubt, please refer to the datasheet on the website or contact EFFILUX. 

 

 

 

 

 

Do not look directly or with any optical instrument the light beam   

 

Avoid any contact with the LED or with the projection lens 

 

IP67 Classification: Do not immerse the product more than 1 meter in depth.  

 

Use the device in an environment at 0°C to +45°C with no excessive moisture: high humidity and high 
temperature could damage the device  

 

Do not use the device in an environment with oil fumes and steam 

 

Do never try to fix any damages to the product by yourself 

 

Make sure you are using a correct power supply before connecting the device 

 

Do not inverse electrical polarity 

 check your connections and the conventions before turning on the power 

supply 

 

Make sure you consider an adapted connector to link the device to the power supply

 

Any improper use voids the warranty

 

 

 

User security 

Содержание Effi-Smart Series

Страница 1: ...any contact with the LED or with the projection lens IP67 Classification Do not immerse the product more than 1 meter in depth Use the device in an environment at 0 C to 45 C with no excessive moistur...

Страница 2: ...an approved anti static mat to cover your work surface CHANGE OPTICAL CONFIGURATION Scheme P1 configuration To handle the optical components wearing gloves is strongly recommended To clean the optica...

Страница 3: ...robe 1 Strobe control triggered on falling edge See DIMMING CONTROL Scheme Not connected 0V Not connected 0V Dimming LED OFF 0V 3V ON 3V 20 10V 100 ON 10 24V 100 3Vdc max 24Vdc 3Vdc max 24Vdc 3Vdc max...

Страница 4: ...update June 17 2020 Mini Parc du Verger B timent E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 38 17 80 Fax 33 9 72 11 21 69 Email contact effilux fr Page 4 4 DIMENSIONS in mm 6 LED 12 LED...

Страница 5: ...ED et avec la lentille de projection Code IP67 Ne pas immerge le produit plus d un m tre de profondeur Utiliser le produit dans un environnement dont la temp rature de travail est situ e entre 0 C et...

Страница 6: ...r la partie plastique 2 Retirer les 2 spacers 4 Vis 2 Spacers Lentille Tournevis Torx Taille T6 D visser les vis du bloc lentille 3 Replacer les l ments dans la bonne configuration 5 Visser les vis du...

Страница 7: ...escendant Voir sch ma contr le DIM Non connect 2 Non connect 2 Cont le DIM LED OFF 0V 3V ON 3V 20 10V 100 ON 10 24V 100 3Vdc max 24Vdc 3Vdc max 24Vdc 3Vdc max 24Vdc Mode Test Les LEDs sont aliment es...

Страница 8: ...17 juin 2020 Mini Parc du Verger B timent E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 38 17 80 Fax 33 9 72 11 21 69 Email contact effilux fr Page 4 4 DIMENSIONS in mm 6 LED 12 LED 36 LED...

Отзывы: