Memory
60 000 measurements
If there is no network connection, the device buffers the
measurements in its internal memory and transfers them to the
platform once the connection is re-established. Once the memory
is full, the oldest measurements are replaced with the new ones
Communication protocols
CoAP (RFC 7252), supports both confirmable and
non-confirmable data frames
Data is sent in Protocol buffers (protobuf)
Bluetooth Low Energy (for communication with smartphones)
SIM card
Micro SIM (3FF) (default)
Embedded SIM (available on request)
Network settings
APN (auto or manual)
PLMN (auto or manual)
Indicators
(troubleshooting)
LEDs singling the status of the device
Device information, which can be requested by the server
include: signal strength in dBm, total power in dBm, TX power in
dBm, cell ID, ECL, SNR, EARFCN, PCI, RSRQ, total transmitted
bytes, total received bytes, battery voltage, uptime
Diagnostics data, including the network parameters and network
connection status, is also available over Bluetooth
Mechanics
Enclosure material: ABS
Size: 27 x 71 x 71 mm, 100 g
Probes length (for sensor with probes only): by default 1 meter,
other lengths are available on request
Operating range: -35°C to +70°C
Mounting: double side adhesive tape with acrylic glue or 2 x M3
screws
Certifications
CE, RoHS
| +48 574 753 980 | [email protected]