I. MOUNTING THE UNIT
1) The unit should be mounted as close to the point of use as possible.
Do not
install the heater above a faucet or “point of use” because the siphoning effect may
drain the heater which can cause premature element burn out. If the unit must be installed at
a higher elevation, you must install spring loaded check valves on both the inlet and outlet of
the water heater.
2) This unit must only be mounted in a vertical position with the
water fittings positioned at
the bottom of the unit
. Mounting other than in the vertical position
will
cause element burn
out and permanent damage to the water heater.
3) The cold water inlet is on the right hand side and the hot water outlet is on the left hand side
as marked by the fittings of the unit. Under
NO
circumstances can these be reversed.
4) Leave a minimum of 8” above the unit for easy replacement of the element.
5) The heater should be fixed to the wall using
all
four mounting holes of the backplate.
Use an appropriate fastener for the weight. For the unit to be mounted against hollow walls,
we suggest using steel wall anchors with the correct grip range, and #10-32 screws at a
minimum.
NOTE: The heater should be installed
below
the level of all hot water outlets serviced by this
NOTE: The heater should be installed
below
the level of all hot water outlets serviced by this
heater. Otherwise install spring loaded check valves on both the inlet and outlet.
NOTE: PRESSURE AND TEMPERATURE RELIEF VALVE
These units are not required by UL to have a Pressure and Temperature Relief
Valve (PTRV). You should check with local codes to find out if one is required in your
area. If local codes require the use of a temperature and pressure relief valve it
should be installed on the outlet hot water pipe before the outlet ball valve.
3
MODELS:
PA
240 - * 1Φ 240V - Series 2
PA
277 - * 1Φ 277V - Series 2
Eemax
Lavatory
Shower
Kitchen
Hot outlet
Cold inlet
Содержание PA014240
Страница 4: ...Mounting Layout for Series 2 Systems 4 Figure 1 ...