background image

 

Tablet, smart phone device 

 

Materials needed: 
 

 

900-230 

CO

2

 Sensor 

 

900-268 WIFI module 

 

900-215 Battery 

 
Prior to initial use the Edu-logger CO

2

 sensor needs to 

be offset. Please review the “Sensor offset” section of 
this  document  on  beginning  on  page  2  for  detailed 
instructions.   
 
Your  CO

2

  sensor needs  to be connected to a  900-268 

module.  The  900-268  module  will  create  a  closed 
Edu-logger  wifi  network  which  will  stream  the  Edu-
logger  data  to  a  device  of  your  choosing.  Once  your 
device  is  wirelessly  connected  to  the  Edu-logger 
network  you  can  run  experiments  and  collect  data 
through a browser of your choosing. 
 

Procedure: 

 

1.

 

Follow  the  „Sensor  Offset”  guide  in  this 
document. 

2.

 

Connect  the  CO

2

  sensor  directly  to  the  left 

side 900-268 (no wires required). 

3.

 

Connect  a  900-215  module  to  the  right  side 
of the 900-268 module. 

4.

 

Although  not  required,  we  recommend 
plugging  the  900-215  to  an  outlet  using  a 
USB to  mini  USB charger (such as a typical 
cell  phone  charger).  The  900-268  module 
will run for 15-75 minutes (depending on the 
sensor) without being plugged in. 

5.

 

The 900-268 can be powered directly using a 
mini  to  USB  cord  and  plugging  it  into  your 
computer  or  a  wall  charger.  Please  note  this 

Содержание 900-230

Страница 1: ...Edu logger CO2 Logger Sensor Guide 900 230...

Страница 2: ...nical cell in the sensor reacts with carbon dioxide to produce a voltage which is directly interpreted to give a CO2 concentration reading Hundreds of possible experiments that can be done with the 90...

Страница 3: ...Needed 900 230 CO2 sensor One of the following depending on experiment type 900 213 USB Module For On line experiments 900 215 Battery For Off line experiments 900 272 Viewing Module and 900 215 Batt...

Страница 4: ...O2 sensor is detected click the Module setup button Hold the probe vertically so the opening is facing the ground Press and hold the blue Start Stop button the faceplate of the sensor for 3 seconds 3...

Страница 5: ...n connects to a computer via a USB to mini USB cable Please note that you cannot plug the CO2 sensor directly into the computer Resident PC software and browser based application can be downloaded for...

Страница 6: ...on this will open a graph below 9 Click on the Module setup button located on the CO2 sensor icon in the module window to change the sensor settings if need be 10 Click on the experiment set up button...

Страница 7: ...sly connected to the Edu logger network you can run experiments and collect data through a browser of your choosing Procedure 1 Follow the Sensor Offset guide in this document 2 Connect the CO2 sensor...

Страница 8: ...e wifi201 com into the URL bar then wait for 30 60 seconds 11 You will see a Control mode icon in the browser click on this icon 12 The browser will then load a new screen and begin to auto detect the...

Страница 9: ...ger viewer Materials needed 900 230 CO2 Sensor 900 272 Viewing Module 900 215 Battery Procedure 1 Follow the Sensor Offset guide in this document 2 Connect the CO2 sensor to the left side of the viewe...

Страница 10: ...en ready to collect data press the Start Stop button on the CO2 sensor a red light will turn on for the duration of the experiment 4 To change the experiment settings first connect to your chosen devi...

Страница 11: ...1 Connect the 900 213 to a PC Mac tablet or smart device 2 Connect the CO2 sensor to a 900 213 module they directly plug together 3 Open the Edu logger software 4 Click the Tools icon 5 Click the Res...

Страница 12: ...ange and operation modes 350 10 000 ppm ADC resolution 14 bit Resolution 1 ppm Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Push button switch for Start S...

Страница 13: ...cientific units o C o F Lux ppm for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded for free at any time using the provided firmware update In s...

Страница 14: ...ion Li2CO3 2Na Na2O 2Li CO2 As a result of the electrochemical reaction electro motive force EMF would be generated according to Nernst s equation EMF Ec R x T 2F ln P CO2 where P CO2 Partial pressure...

Страница 15: ...e CO2 sensor s probe upright with the blue rubber tip pointing downward Do not use the sensor in acid or alkaline solutions with a molarity greater than 1 0 Warranty We promise to deliver our sensor f...

Страница 16: ...16 Thank you for using Edu logger Flexible simple fast forward thinking W www edulab com E info edulab com V10012013...

Отзывы: