250714103200
16
16
Troubleshooting
Is there fuel in the
tank?
Refill the fuel tank
Is the engine switch
ON?
Turn the engine
switch on
Add the
recommended oil
Is there enough oil
in the engine?
If the engine still
does not start, take
the generator to an
authorised service
center.
Clean, re-adjust the
gap and dry the
spark plug. Replace
it if necessary
The Engine Will Not Start
Is the output
indicator ON?
Disconnect the
electrical
appliances. Stop
and re-start the
engine.
Are all circuit
breakers ON?
Check the electrical
appliance or
equipment for any
defects.
Plug in your
appliances
(spread the load
over all 240V outlets
if your purchased a
3-Phase)
Switch all circuit
breakers to “ON”
Take the generator
to an authorised
service center.
Turn all circuit
breakers ON.
- Replace the electrical appliance or equipment.
- Take the electrical appliance or equipment to an
electrical repair shop for repair.
Take the generator
to an authorised
service center.
No power from outlet socket
If ‘yes’
If ‘yes’
If ‘yes’
If ‘yes’
If ‘yes’
If ‘no’
If ‘no’
If ‘no’
If ‘no’
If ‘no’
If ‘no’
If ‘no’
If ‘no’ fault
Is the output
indicator ON?
If ‘yes’
Is the engine
running?
Start Engine
If ‘yes’
If ‘no’
fault
Switch on your
appliances one-by-
one taking care not
to overload the
generator
Is it a Diesel
Engine?
If ‘yes’
Is the spark plug in
good condition?
If ‘no’
If ‘yes’
Could there be an
air lock or bubbles
in the fuel line?
If ‘no’
Re-Prime the Fuel
line system.
See section in
manual.
If ‘yes’
Determine if
“overloaded”
If ‘yes’
If ‘no’
Reduce the load on
your generator by
removing some of
your appliances