background image

 

250714103200 

 

16 

16 

Troubleshooting 

Is there fuel in the 

tank?

Refill the fuel tank

Is the engine switch 

ON?

Turn the engine 

switch on

Add the 

recommended oil

Is there enough oil 

in the engine?

If the engine still 

does not start, take 
the generator to an 

authorised service 

center.

Clean, re-adjust the 

gap and dry the 

spark plug. Replace 

it if necessary

The Engine Will Not Start

Is the output 

indicator ON?

Disconnect the 

electrical 

appliances. Stop 

and re-start the 

engine.

Are all circuit 

breakers ON?

Check the electrical 
appliance or 
equipment for any 
defects.

Plug in your 

appliances 

(spread the load 

over all 240V outlets 

if your purchased a 

3-Phase)

Switch all circuit 

breakers to “ON”

Take the generator 

to an authorised 

service center.

Turn all circuit 

breakers ON.

- Replace the electrical appliance or equipment.
- Take the electrical appliance or equipment to an 
electrical repair shop for repair.

Take the generator 

to an authorised 

service center.

No power from outlet socket

If ‘yes’

If ‘yes’

If ‘yes’

If ‘yes’

If ‘yes’

If ‘no’

If ‘no’

If ‘no’

If ‘no’

If ‘no’

If ‘no’

If ‘no’

If ‘no’ fault

Is the output 

indicator ON?

If ‘yes’

Is the engine 

running?

Start Engine

If ‘yes’

If ‘no’

 fault

Switch on your 

appliances one-by-

one taking care not 

to overload the 

generator

Is it a Diesel 

Engine?

If ‘yes’

Is the spark plug in 

good condition?

If ‘no’

If ‘yes’

Could there be an 

air lock or bubbles 

in the fuel line?

If ‘no’

Re-Prime the Fuel 

line system.

See section in 

manual.

If ‘yes’

Determine if 

“overloaded”

If ‘yes’

If ‘no’

Reduce the load on 

your generator by 
removing some of 

your appliances

 

Содержание DSLGEN-6500S

Страница 1: ...re and or serious injury Save this manual for future reference ATTENTION Products covered by this manual will vary in appearance assembly inclusions description and packaging NOTE This manual covers m...

Страница 2: ...Parts Diagram 4 Before use 6 Starting the engine 7 Stopping the Engine 8 Re Priming the fuel system 8 Using your Generator 9 Maintenance 12 Service Schedule 14 Transporting Storage 15 Troubleshooting...

Страница 3: ...uring a power outage Improper connections may cause the generator to explode burn or cause fires in the building s electrical system Transporting the Generator The engine should be turned off when the...

Страница 4: ...familiar with safe operation handling of this machine or are in any way unsure of any object of this products suitability or correct use for your application you should complete training conducted by...

Страница 5: ...haust Outlet 3 Handle a 4 Fuel Guage 5 Fuel filler cap 6 Black control panel 7 Front access panel 8 Wheels 9 Wheel covers 10 Handle b 11 Rear Access Panel 12 Air filter service panel Control Panel s 1...

Страница 6: ...250714103200 5 5 Engine 1 Oil Filter location 2 Oil Filter locking bolt 3 Oil Filter strainer 4 Run Lever 5 Emergency OFF lever 6 Oil filler cap 7 Oil drain bolt...

Страница 7: ...The battery is self charging through general use however there may be need on occasion to remove the battery and charge it with an appropriate charger or jump start Fitting the Wheels applicable model...

Страница 8: ...e emitted from a new engine for the first 5 hours of use while running in 1 Clean surface around fuel cap to prevent contamination 2 Loosen fuel cap slowly Rest the cap on a clean surface 3 Carefully...

Страница 9: ...move the red shut down lever to the stop position In normal use 1 Switch OFF all connected equipment and pull the inserted plug s out 2 Switch OFF any protective switches circuit breakers 3 Turn the...

Страница 10: ...ch 10 hours of use NOTE Never run the engine without the air cleaner Rapid engine wear will result from contaminants such as dust and dirt being drawn through the carburettor into the engine See secti...

Страница 11: ...acle may be used while the AC power is in use An overloaded DC circuit will trip the DC circuit protector If this happens unload the DC load before pushing in the circuit protector to resume operation...

Страница 12: ...rator can cause damage and void warranty IMPORTANT Only one third of the total generator capacity is available from any single phase 240v outlet WARNING 3 Phase generators are not suitable for running...

Страница 13: ...warm but not hot to assure rapid and complete draining IMPORTANT Make sure to turn the engine switch OFF before draining NOTE When the oil is drained it is an optimal time to clean the oil filter stra...

Страница 14: ...remove debris and any degreaser left behind 4 Replace the Oil filter strainer followed by the oil filter locking bolt IMPORTANT Please dispose of used motor oil in a manner that is compatible with the...

Страница 15: ...250714103200 14 14 Service Schedule...

Страница 16: ...overfill the tank there should be no fuel in the filler neck WARNING Avoid a place exposed to direct sunlight when putting the generator on a vehicle If the generator is left in an enclosed vehicle f...

Страница 17: ...breakers to ON Take the generator to an authorised service center Turn all circuit breakers ON Replace the electrical appliance or equipment Take the electrical appliance or equipment to an electrical...

Страница 18: ...ox 1 3 of the total generator output e g 7amps OSE Max output 10kVA cos 08 Other Seller Equivalent DC Output 12V 8 3A Starting Method Electric Key Start Engine Oil Type Acceptable Oil Grades 10W30 10W...

Страница 19: ...250714103200 18 18 Appendix Copyright 2012 Mills International Trading Pty Ltd...

Страница 20: ...n access to the product The product has been supplied by a general merchandise retailer that may not be familiar with your specific applic ation or your description of the application Be sure to attai...

Отзывы: