Auto Range Digital Clamp Meter - True RMS 1000A AC/DC

• Follow all safety and operating instructions to ensure maximum personal 

safety during the operation and to ensure the meter is used safely and is kept 
in good operating condition.

• Read the operating instructions thoroughly and completely before operating 

your meter.

• Pay attention to WARNINGS, which will inform you of potentially dangerous 

procedures. The instructions in these warnings MUST be followed.

• Always inspect your meter and test leads for any sign of damage or 

abnormality before every use. If any abnormal conditions exist (i.e. broken test 
leads, cracked cases, display not reading, etc.). DO NOT attempt to take any 
measurements.

• Please DO NOT store or use meter in areas exposed to direct sunlight, high 

temperature, humidity or condensation.

• Never ground yourself when taking electrical measurements. Keep your body 

isolated from ground by using dry clothing, rubber shoes, rubber mat or any 
approved insulating material.

• Be careful when working with voltages above 60V DC or 30V AC rms. Keep 

fingers behind the probe barriers while measuring.

• To avoid damages to the instrument, NEVER exceed the maximum limits of the 

input values shown in the technical specification tables.

• Never use the meter to measure voltages that might exceed the maximum 

allowable input value of any function.

• Never touch exposed wiring, connections or  any live circuit when attempting 

to take measurements.

• Before rotating the range selector to change functions or opening the battery 

case, ALWAYS disconnect test leads from the circuit under test. 

• Never use the meter unless the back cover is in place and fastened completely.
• Do not use abrasives or solvents on the meter. To clean it using a damp (not 

wet) cloth and mild detergent only.

• Qualified and trained service technicians should only perform calibration and 

repair of the meter.

1.2. Symbols

Important safety information, refer to the operating manual.

Dangerous voltage may be present.

Earth ground.

Double insulation (Protection class 1000V CAT II 600V CAT III).

5163840K_Instructions.qxd  22/09/2009  08:46  Page 3

Содержание DCM007

Страница 1: ...MANUAL F Fu un nc ct ti io on ns s T Te el le ep ph ho on ne e n ne et tw wo or rk k t te es st ti in ng g F Fu us se e c co on nn ne ec ct ti io on n t te es st ti in ng g ORDER CODE EDI 516 3840K M...

Страница 2: ...vicinity of the equipment may disturb the measurement circuit Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit Users should exercise care...

Страница 3: ...ny approved insulating material Be careful when working with voltages above 60V DC or 30V AC rms Keep fingers behind the probe barriers while measuring To avoid damages to the instrument NEVER exceed...

Страница 4: ...or R Ri ig gg ge er r clamp lever Press the lever to open the transformer When the lever is released the jaws will close again R Ro ot ta ar ry y d di ia al l Used to select functions F FU UN NC C but...

Страница 5: ...asurements except current Connection is made to it using the black test lead V V H Hz z jack This is positive input terminal for volt resistance frequency diode and Continuity test Connection is made...

Страница 6: ...ual range 3 Press the trigger to open transformer jaw and to clamp one conductor only making sure that the jaw is firmly closed around the conductor 4 Read the measure result from the display N NO OT...

Страница 7: ...m value of the range or the input is not connected an overrange indication OL will be display When checking in circuit resistance be sure the circuit under test has all power removed and that all capa...

Страница 8: ...is positive 4 Read the measure result from the display N NO OT TE E The signal amplitude must also be greater than the sensitivity level Determine that the amplitude level of the signal to be measured...

Страница 9: ...ts Updates 2 3 sec Ranging method Auto manual range mode Polarity indication __ display for negative polarity Overrange indication LCD will display OL Low battery will appears on LCD Jaw capability 40...

Страница 10: ...x 5 5 Resistance RANGE RESOLUTION ACCURACY 400A 0 1A 3 0 of rdg 5 digits 600A 1A 1000A 1A 3 0 of rdg 6 digits RANGE RESOLUTION ACCURACY 400A 0 1A 2 5 of rdg 5 digits 600A 1A 1000A 1A 3 0 of rdg 6 digi...

Страница 11: ...ovided If no function changes occur after about 30 minutes the meter will be turned off automatically To turn the power back On push the F FU UN NC C button only RANGE RESOLUTION ACCURACY 40Hz 0 01Hz...

Страница 12: ...isture related contamination Before replacing the battery and fuses disconnect test leads from any circuit under test turn the multimeter OFF and remove test leads from the input terminals To prevent...

Страница 13: ...covers and screw securely back into place The multimeter should now be fully functional CAUTION Please be aware that using the clamp meter in an environment with a strong radiated radio frequency elec...

Страница 14: ...14 NOTES 5163840K_Instructions qxd 22 09 2009 08 46 Page 14...

Страница 15: ...15 Auto Range Digital Clamp Meter True RMS 1000A AC DC 5163840K_Instructions qxd 22 09 2009 08 46 Page 15...

Страница 16: ...developed and improved All details and illustrations are for guidance and may be subject to change EDISON The Power Factory PO Box 14 Wigston Leicester England ISO 9001 Registered Company 5163840K_Ins...

Отзывы: