113
MIDI implementation
●
Program change
Status
2nd byte
CnH
ppH
n = MIDI channel number:
0H – FH (Ch.1 – 16)
pp = Program number:
00H – 7FH (prog. 1 – prog. 128)
*
Transmitted in Program change mode.
●
Channel pressure
Status
2nd byte
DnH
vvH
n = MIDI channel number:
0H – FH (Ch.1 – 16)
vv = Channel pressure:
00H – 7FH (0 – 127)
●
Pitch bend change
Status
2nd byte
3rd byte
EnH
llH
mmH
n = MIDI channel number:
0H – FH (Ch.1 – 16)
mm, ll = Pitch Bend value:
00 00H – 40 00H – 7FH 7FH
(-8192 – 0 – +8191)
*
Transmitted by rightward/leftward operation of the BENDER lever in Play
mode.
■
Channel mode messages
In addition to the channel mode messages that can be transmitted in Panic mode,
the PCR-M30/50/80 lets you assign any channel voice message to any controller
and transmit it.
●
Channel mode messages
Status
2nd byte
3rd byte
BnH
ccH
vvH
n = MIDI channel number:
0H – FH (Ch.1 – 16)
cc = controller number:
78H – 7FH
vv = control value:
00H – 7FH
❍
All sounds off (Controller number 120)
Status
2nd byte
3rd byte
BnH
78H
00H
n = MIDI channel number:
0H – FH (Ch.1 – 16)
*
Transmitted in Panic mode.
❍
Reset all controllers (Controller number 121)
Status
2nd byte
3rd byte
BnH
79H
00H
n = MIDI channel number:
0H – FH (Ch.1 – 16)
*
Transmitted in Panic mode.
❍
All notes off (Controller number 123)
Status
2nd byte
3rd byte
BnH
7BH
00H
n = MIDI channel number:
0H – FH (Ch.1 – 16)
*
Transmitted in Panic mode.
■
System common message
On the PCR-M30/50/80 you can assign the following system common messages to
any controller and transmit them.
●
MTC quarter frame
Status
2nd byte
F1H
mmH
mm = Message type/value
●
Song position pointer
Status
2nd byte
3rd byte
F2H
mmH
llH
mm, ll = Song position:
00 00H - 7F 7FH (0-16383)
●
Song select
Status
2nd byte
F3H
mmH
mm = Song number:
00 00H - 7F 7FH (0-16383)
●
Tune request
Status
F6H
■
System realtime message
In addition to the Active Sensing messages that are transmitted constantly, the
PCR-M30/50/80 allows you to assign the following system realtime messages
(other than Active Sensing) to any controller and transmit them.
●
Timing clock
Status
F8H
*
Transmitted if the System setting F8 CLOCK is ON.
●
Start
Status
FAH
●
Continue
Status
FBH
●
Stop
Status
FCH
●
Active sensing
Status
FEH
*
Transmitted at intervals of approximately 250 ms.
*
Cannot be assigned to a controller.
●
System reset
Status
FFH
PCR-M30/50/80.book 113 ページ 2005年11月10日 木曜日 午後2時49分