THE FLUE

:

Further to the general prescriptions for the fumes duct 
and flue, the flue:
•  must serve solely to exhaust fumes
•  must be correctly sized to satisfy the requirements 

of fumes exhaust (EN 13384-1)

•  should preferably be insulated, in steel with a 

circular internal section. If rectangular, the corners 
must have a radius of not less than 20 mm, with a 
ratio of the internal dimensions of <1.5

•  must normally be at least 1.5 metres in vertical 

length

•  must have a constant cross section
•  must be waterproof and thermally insulated to 

ensure a good draw

•  must preferable have a collection chamber for
•  If pre-existing, must be clean, to prevent the fire 

hazard.

•  in general, we recommend fitting a tube inside the 

existing masonry chimney if its diameter is greater 
than 150 mm.

INTUBATED SYSTEM

:

Further to the general prescriptions for the fumes duct 
and flue, the intubated system:
•  must operate in negative pressure;
•  must be open to inspection
•  must observe local regulations. 

THE CHIMNEY POT 

•  must be windproof 
•  must have an internal cross section equivalent to 

that of the flue and a fumes outlet at least double 
that of the interior of the flue

•  for dual flues (which should be spaced at least 2 

m apart) the chimney pot receiving the fumes from 
the solid fuel appliance or that from the higher 
storey, must be at least 50 cm higher than the other

•  it must extend beyond the back flow zone (in Italy, 

refer to UNI 10683 point 6.5.8.)

•  it must allow for maintenance of the chimney

EXTERNAL AIR INTAKE 

In general, we suggest two ways for ensuring a proper 
flow of combustion air.

Indirect air intake

Install an intake at floor level with effective area (net of 
the mesh or other protective equipment) of at least 80 
cm

2

 (10 cm dia.).

To prevent draughts, we recommend installing the 
intake behind the stove or behind a radiator.
Installing it in front of the appliance will create 
unpleasant draughts.

Direct air intake

Install an air intake of effective area (net of the mesh or 
other protective equipment) at least equal to that of the 
air intake at the back of the product.
Connect the air intake to the appliance’s air intake with 
a tube (which may also be flexible).
We recommend not exceeding a 5 m length and not 
curving the tube at most 3 time, depending on the 
draw of the flue.

The air maty be drawn from an adjacent room only if:
•  the flow is taken from permanent and unobstructed 

openings communicating with the outdoors;

•  the adjacent room is never in underpressure 

relative to the outdoors;

•  the adjacent room is not a garage. subject to fire 

hazard, a bathroom or bedroom

•  the adjacent room is not a shared room in the 

condominium.

INSTALLATION

Ducting of heating air

To duct the warm air exiting the rear (protected as 
standard by a grille), you will find several optional 
extras at your reseller:
•  air duct pipe (3 metres, 6 cm diameter)
•  “Y” deviation for duct pipe (6 cm diameter)
•  various models of ducting vents (Bent, Split, 

Origami, Sharp). The instructions for connecting 
these vents are given in the manual provided with 
the vents.

Содержание NARA PLUS

Страница 1: ...NARA PLUS PELLET STOVE UK Installation use and maintenance ...

Страница 2: ...IN model NARA PLUS SERIAL NUMBER Nameplate reference Performance declaration DoP EK n 153 Nameplate reference And also declares that the NARA PLUSwood pellet stove satisfies the requirements of the following European directives 2014 35 EC Low Voltage Directive 2014 30 EC Electromagnetic Compatibility Directive Safety information 4 Dimensions 5 Technical characteristics 6 Packaging 7 Installation 7...

Страница 3: ...rted up for the first time commissioned by a qualified Edilkamin technician In Italy commissioning by an authorised technician is required by UNI 10683 and is recommended in all countries to ensure best results from the product This consists in checking the installation documents declaration of conformity and the quality of the installation itself calibrating the product to suit its actual applica...

Страница 4: ...vironmental damage may ensue cleaning the hearth when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT IS HOT Risk of damage to the cleaner and smoke in the room cleaningthefumesductwithcleaningproducts DO NOT CLEAN THE PRODUCT WITH FLAMMABLE PRODUCTS Risk of fire and blowback cleaning the hot glass pane with unsuitable cleaning products DO NOT CLEAN THE GLASS WHILE IT IS HOT WITH WATER ...

Страница 5: ...tlet 46 Ø 4 cm aria combustione 99 11 18 46 49 49 Ø 8 cm uscita fumi 39 6 99 46 Ø 4 cm aria combustione 99 11 18 46 49 49 Ø 8 cm uscita fumi 39 6 99 46 Ø 4 cm aria combustione 99 11 18 46 49 49 Ø 8 cm uscita fumi 39 6 99 99 46 49 46 99 49 6 13 14 18 39 24 5 Ø 6 cm warm air ...

Страница 6: ...le 80 mm Air intake diameter male 40 mm Weight including packaging 130 kg TECHNICAL DATA FOR RATING THE FLUE which must in any case satisfy the requirements of this sheet and the installation instructions for the product Nominal power Reduced power Fumes temperature at outlet 168 100 C Minimum draw 0 01 Pa Fumes flow rate 6 8 2 6 g s ELECTRICAL SPECIFICATIONS Power 230 Vac 10 50 Hz Mean absorbed p...

Страница 7: ...vance of safety regulations Do not turn the package over and handle all parts requiring installation with care Contents of the bag of small parts n 6 rods for the three ceramic top parts n 6 ceramic dampers for the top n 6 shims for adjusting the ceramic parts on the top n 8 M4 bolts and 8 washers for the four ceramic side panels 2 per side n 1 countersunk screw M 4x8 for the low ceramic element o...

Страница 8: ...ff the pallet by removing the screws PLEASE NOTE DO NOT ATTEMPT TO TAKE THE STOVE OFF THE PALLET WITHOUT FIRST REMOVING THE SIDE PANELS AND THE SCREWS TWO PER SIDE ANCHORING THE STOVE TO THE PALLET The drawings are indicative and valid for mounting the covering They may not refer to the specific model ...

Страница 9: ...e side panels with the bolts and washers included in the bag of small parts On the lower right side use the countersunk screw M 4x8 provided to avoid interference with the internal parts bolts washers Do not force the screw into the threaded bushingit may break x 2 x 2 ...

Страница 10: ...10 ENGLISH INSTALLATION Fit the interlocking side panels and screw down the bolts on the back ...

Страница 11: ...STALLATION Fit the dampers onto the top Screw the rods into the top ceramics 2 rods for each ceramic part Please apply high temperature silicone under the holes A to strengthen the stability of the component A A A A ...

Страница 12: ...12 ENGLISH INSTALLATION Position the three ceramic parts on the top use the shims to adjust the ceramics if they are slightly misaligned this is perfectly normal ...

Страница 13: ...any area with an explosive atmosphere Any extraction fans operating in the same room or area as the product may affect its draw Protection from heat and safety clearances The surfaces of the building adjacent to the product must be protected against overheating The insulation to be used will depend on the type of surface in question The product must be installed in observance of the following safe...

Страница 14: ...te at roof level with a proper chimney pot the flue may not discharge directly from the wall or into an enclosed space even if the space in question is open to the sky be made of material rated fire reaction class A1 per UNI EN 13501 or analogous national regulations be certified with a chimney plate if metal be of uniform cross section or vary in cross section only immediately after the outlet no...

Страница 15: ...o UNI 10683 point 6 5 8 it must allow for maintenance of the chimney EXTERNAL AIR INTAKE In general we suggest two ways for ensuring a proper flow of combustion air Indirect air intake Install an intake at floor level with effective area net of the mesh or other protective equipment of at least 80 cm2 10 cm dia To prevent draughts we recommend installing the intake behind the stove or behind a rad...

Страница 16: ... from the appliance manuals labels etc Make sure to remove the labels on the glass There may be a slight smell of paint the first few times it is ignited however this will disappear quickly INSTALLATION LOADING THE PELLETS INTO THE PELLET TANK To access the tank open the lid Use BS EN ISO 17225 2 category A1 wood pellets or similar certified products with the following characteristics diameter 6 m...

Страница 17: ...rther to the above operational procedures the stove has the following phases Ignition display reads ON Flame ignites and grows stable This is the result of manual ignition with ignition button request from Crono power request during stand by request from external contact Ignition has a variable duration with the aim of reaching the start temperature Switch off display reads OFF The flame is exting...

Страница 18: ...imate value since it depends on both the type of batteries and the intensity of use Edilkamin and the reseller will not consider claims for battery life under any circumstances If the battery charge is low a warning displays at the top left REMOTE CONTROL POWER SAVING If the remote is not used for 20 the display turns off to save power The display turns black without text This condition refers sol...

Страница 19: ...uce heat The display shows figure 4 1 the current time 2 the current room temperature 3 the room temperature setting or manual mode 4 the power level represented by the flames 5 the fan level represented by the filling in of the blades If timer programming is active 3 and 4 are replaced by the day s timer programming with the current setpoint at the centre figure 5 and the temperature displayed at...

Страница 20: ...he and buttons The power level displays next to the flame symbol Ventilation The product is equipped with two fans defined in the control logic as fan 1 and 2 and displayed as positions 1 and 2 see below The two fans can be adjusted separately First adjust fan 1 and then fan 2 as described below Ventilation setting Follow the instructions below to manually regulate the power levels of fans 1 2 Pre...

Страница 21: ...he temperature setpoint is reached To access the function from the main menu as indicated in the Menu section above press the M button Scroll using the buttons and select the function by pressing OK Use the buttons to select OFF or ON Press M to quit without saving Press OK for two seconds to confirm and return to the previous menu level If you selected ON the display shows the minutes for which t...

Страница 22: ...press the M button LOAD PELLETS STAND BY CRONO NIGHT DATE TIME DISPLAY LANGUAGE BEEP INFO TECHNICAL MENU scroll buttons OK button to confirm The following screen will appear Scroll to ENABLE underlined using the buttons To enable the Crono function to 7 days a week or on single days ENABLE on the display press the OK button To go back to the previous screen press the M button ENABLE TEMP CHANGE SE...

Страница 23: ... buttons Press the OK button to confirm and select SET Press the M button to go back to the previous screen press the OK button to enter the SET function ENABLE TEMP CHANGE SET scroll buttons OK button to confirm The first page below allows you to choose whether to apply the same Crono configuration for 7 7 days 5 7 weekend only or day by day The Crono has three adjustable setpoints T1 T2 and T3 s...

Страница 24: ...ickly Press the OK button to confirm and go to the temperature selection T1 T2 or T3 Press the buttons to switch between the temperatures To continue with other changes press the OK button To choose between exit without saving and save press the M button The following screen will appear Press M to exit without saving Press OK to save and go back to the screen To view change the settings CHANGE on ...

Страница 25: ...an during commissioning Available only in the OFF state If you attempt to activate the function in other states access is not granted To access the function from the main menu as indicated in the Menu section above press the M button Scroll using the buttons and select the function by pressing OK Use the buttons to activate deactivate the function Press M to quit without saving Confirm by pressing...

Страница 26: ...g Confirm by pressing the OK button for 2 seconds Beep Allows you to enable disable the beep To access the function from the main menu as indicated in the Menu section above press the M button Scroll using the buttons and select the function by pressing OK Use the buttons to select On Off Press M to quit without saving Confirm by pressing the OK button for 2 seconds Info These readings should only...

Страница 27: ...ff cold and unplugged from the power supply Cleaning must be carried out with a vacuum cleaner Open the door extract the fire box 1 fig A DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER Pull the ash drawer out and empty it into a non flammable container the ash may still have some parts that are hot and or embers Vacuum out the inside of the fire box fire grate and space around the fire box in...

Страница 28: ...ioned Note that using the stove without cleaning the grate can cause the gas in the combustion chamber to ignite and break the door glass FIG D MAINTENANCE Once you have finished cleaning the stove make sure the grate is PROPERLY SEATED A fig D failure to do so can cause the stove to malfunction Before starting up the stove make sure the grate is seated properly as shown in fig E without ash or un...

Страница 29: ...parts may damage the appliance and relieves Edilkamin of all liability for damage resulting therefrom DISPOSAL At the end of its service life dispose of the product as required by regulations Deliver to the special recycling centres In accordance with art 26 of Legislative Decree no 49 of 14th March 2014 Implementation of Directive 2012 19 UE on the disposal of electrical and electronic devices RA...

Страница 30: ...when the combustion air intake is below the set level Check that the hearth door is closed Check that the stove exhaust and combustion air duct are clean H02 displays when the logic board is not detecting the right fumes fan speed Contact the technician H03 displays when the thermocou ple detects a fume temperature lower than the set value and in terprets this as the absence of flame Check that th...

Страница 31: ...ician MESSAGE PROBLEM SOLUTION H07 Shutdown due to exceeding maximum fumes temperature Check the type of pellet contact the technician if in doubt Contact the technician H08 Shutdown due to overheating in the product please see H07 H09 Shutdown due to gearmotor failure Contact the technician H10 Shutdown due to exceeding maximum motherboard temperature Contact the technician H11 Shutdown for press...

Страница 32: ...cod 941381 GB 06 18 D w w w e d i l k a m i n c o m 941381 GB ...