EdilKamin Iris Plus Скачать руководство пользователя страница 16

page 16

Warranty for your pellet fire (Iris Plus & Little models)

Warranty 

Your EdilKamin Pellet fire is covered by a full twelve month 
warranty, and a three year firebox warranty. 

Standard EdilKamin Warranty 

(NZ Consumer laws apply to this warranty)

Pioneer Manufacturing Limited warrants the cast iron firebox 
against defective materials and workmanship which would 
render it unfit for normal domestic use within a period of three 
years after date of original purchase.

All other parts including electrical components, door, door seal 
and glass, are warranted for a period of one year from date of 
original purchase for domestic use against defective materials 
and workmanship.

Warranty Conditions:

•   The heater must be installed, operated and maintained 

strictly in accordance with the building code and the 
manufacturer’s installation and operation manuals.

•   This warranty covers replacement or repair at the 

manufacturer’s discretion but excludes freight, travel and/ 
or any other associated costs.

•   Operation of this appliance in violation of the warnings 

in the operation and installation manual will void this 
warranty.

•   Failure to do the necessary inspection & maintenance 

of this appliance in accordance to the instructions in the 
operation manual will void this warranty. It is critical that 
the fire not be operated with faulty or missing door seals, 

cracked or broken door glass. These require regular 

inspection/maintenance and if not maintained will void the 
firebox warranty

•   The manufacturer or their agents are not liable for any loss 

or expense direct or indirect arising from the failure of any 
part or operation of the appliance.

•   A claim under this warranty should be directed to the 

retailer who supplied the EdilKamin Pellet fire, or if this is 
not possible write direct to the manufacturer stating details 
of fault, serial number of your EdilKamin Pellet fire, proof of 
purchase and name of retailer.

Warranty Exclusions:

This Manufacturers Warranty DOES NOT cover:

•   Service calls which are not related to any defect in the 

Product (I.e operational, installation or fuel issues). The 

cost of a service call will be charged if the problem is not 
found to be a product fault.

•   Defects caused by factors other than normal domestic use 

or use in accordance with the product’s operation manual.

•   Defects to the Product caused by accident, neglect, 

misuse or act of God. [eg: broken ceramics, power surges 

etc]

•   The cost of repairs carried out by non-authorised repairers 

or the cost of correcting such unauthorised repairs.

•   Normal recommended maintenance as set out in the 

Product’s Owners Operation Manual.

Service under this manufacturer’s warranty must be provided 

by a repairer authorised by Pioneer Manufacturing Limited. 

Such service shall be provided during normal business hours.

Pioneer Manufacturing Limited reserves the right change 
details without notice

Standards and Compliance Declaration:

The Iris Plus and Little Pellet Fires have been tested and 
comply with: AS/NZS 2918:2001, AS/NZS 4886:2007, AS/
NZS 5078:2007, EN60355-1:2002 and EMC EN55014-1:2000

The Iris Plus and Little Pellet Fires have been manufactured by 
EdilKamin, a UNI EN ISO 9001 certified company.

GADGET6872 02/11

Mamaku Street, Inglewood 4330, New Zealand
PO Box 11, Inglewood 4347, New Zealand

Ph (06) 756 6520 •  Fax (06) 756 6540
[email protected] • www.metrofires.co.nz

Содержание Iris Plus

Страница 1: ...Manual Important information 2 Operation and fuel 3 Technical specifications 4 Assembly installation 5 Pellet fire vent systems 6 Dimensions 8 Installation clearances 9 Control panels weekly timer 10...

Страница 2: ...eded Please take particular note of the following Never put foreign substances in the firebox or hopper Do not use flammable products to clean the smoke duct Firebox and hopper components must only be...

Страница 3: ...filled through a lid found at the back of the top The internal structure of the pellet fire is completely made of cast iron The external covering of the Iris Plus is ceramic and the external covering...

Страница 4: ...optional infrared Electronic circuit board protection 5 x 20 2 A 250 VAC fuse IRIS PLUS TECHNICAL HEATING SPECIFICATIONS Hopper capacity 15kg Efficiency 71 Heat Output 3 4 8kW Burn time min max 7 5 1...

Страница 5: ...the vent system will be clear of ceiling joists trusses etc 9 Once you are satisfied you have the pellet re in its final position secure it to the oor using suitable anchors Drill through the oor prot...

Страница 6: ...he air intake through the pellet fire and pushes it out the venting Air passing through the burn pot is used to burn the pellets Proper vent pipe sizing is very important to ensure the pellet fire ope...

Страница 7: ...We recommend sufficient space be provided minimum 200mm on each side of the pellet fire to service the unit If this is not possible provision must be made available to remove the unit for servicing Pe...

Страница 8: ...PROFILE Little Iris Plus Little FRONT PROFILE Little REAR PROFILE IRIS PLUS side PROFILE IRIS PLUS FRONT PROFILE IRIS PLUS REAR PROFILE 600mm 480mm 600mm 950mm 375mm 320mm 500mm 530mm 215mm 106mm 77...

Страница 9: ...ry hour There are three methods of supplying the pellet fire with combustion air They are as follows DV WALL KIT ducts through an outside wall DV FLOOR KIT ducts through the floor directly behind the...

Страница 10: ...able to pick up Ignition Automatic ignition Hold the 0 1 key down for two seconds with the pellet fire on standby to start the ignition procedure Ac appears on the display for a few minutes the igniti...

Страница 11: ...been enabled If so you can exit thie section by pressing O 1 and proceed to setting program section 4 Press the MENU key until OFF appears 5 Press the or key until PrOn appears 6 Confirm with the MENU...

Страница 12: ...OFF key down for two seconds with the pellet fire on standby to start the ignition procedure Ac will appear on the display for a few minutes The ignition procedure does not have a set duration it is a...

Страница 13: ...isplayed if programming has previously been enabled If so you can exit thie section by pressing O 1 and proceed to setting program section 4 Confirm by pressing the Menu key pass now to on with the or...

Страница 14: ...ion is suspected If the value displayed does not vary when the conditions are changed for example the door is opened then the sensor is faulty The low pressure alarm may also occur during ignition as...

Страница 15: ...ing a vacuum pot connected to your vacuum cleaner which are available from your Metro Dealer The whole process takes only a few minutes a day Vacuum clean the door vacuum clean the hearth and vacuum c...

Страница 16: ...arising from the failure of any part or operation of the appliance A claim under this warranty should be directed to the retailer who supplied the EdilKamin Pellet fire or if this is not possible wri...

Отзывы: