iCITE
®
DA-Data Aggregator
®
DA-400™
and
iCITE
®
Installation Manual
Eberle Design Inc.
Page
6
NOTE
1:
Digital inputs are voltage based, and are referenced to the Logic Ground provided
on H7.
NOTE
2:
Typical input impedance is 150K Ohm.
NOTE
3:
Each input pin can have a pull-up resistor connected by applying a pull-up voltage
(typically 12VDC or 24VDC) to the associated Pull up VREF pin.
DA-500E H-5 (Digital DC Inputs)
Pin
WIRE
MARKING
WIRE
COLOR
TYPICAL
VOLTAGE
RANGE
MAXIMUM
VOLTAGE
RANGE
THRESHOLD Pull up
Power
Pin
FUNCTION
A1
DETECTOR9
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF2 Input from detector
output 9
A2
DETECTOR10
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF2 Input from detector
output 10
A3
DETECTOR11
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF2 Input from detector
output 11
A4
DETECTOR12
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF2 Input from detector
output 12
A5
DETECTOR13
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF2 Input from detector
output 13
A6
DETECTOR14
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF2 Input from detector
output 14
A7
DETECTOR15
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF2 Input from detector
output 15
A8
DETECTOR16
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF2 Input from detector
output 16
A9
VREF2
RED
12 OR 24
VDC
0-62 VDC
Reference pull up
voltage for Detectors 9-
16
A10 -
-
(internally connected to
logic ground
A11 PED3
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF3 Input from Ped Isolator 3
A12 PED4
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF3 Input from Ped Isolator 4
B1
DETECTOR1
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF1 Input from detector
output 1
B2
DETECTOR2
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF1 Input from detector
output 2
B3
DETECTOR3
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF1 Input from detector
output 3
B4
DETECTOR4
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF1 Input from detector
output 4
B5
DETECTOR5
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF1 Input from detector
output 5
B6
DETECTOR6
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF1 Input from detector
output 6
B7
DETECTOR7
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF1 Input from detector
output 7
B8
DETECTOR8
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF1 Input from detector
output 8
B9
VREF1
RED
12 OR 24
VDC
0-62 VDC
Reference pull up
voltage for Ped 1-4
B10 VREF3
RED
12 OR 24
VDC
0-62 VDC
Reference pull up
voltage for Detectors 1-4
B11 PED1
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF3 Input from Ped Isolator 1
B12 PED2
BLUE
0-28 VDC 0-120 VDC 2.5, 3, 6, 12 V VREF3 Input from Ped Isolator 2
Table 1 H-5 Harness Inputs