CMUip-2212 Cabinet Monitor Unit
Operations Manual
Eberle Design Inc.
Page 26
Pin #
Function
Pin #
Function
A9
SB1 T
B9
SB1 TxClock -
A10
SB1 R
B10
SB1 RxClock -
A11
Reserved
B11
Reserved
A12
Reserved
B12
Reserved
A13
Reserved
B13
Reserved
A14
Reserved
B14
Reserved
A15
Line Sync +
B15
Line Sync -
A16
B16
Nreset -
A17
Pow
B17
PowerDown -
A18
SB3
B18
SB3 TxData -
A19
SB3
B19
SB3 RxData -
A20
SB3 Clock+
B20
SB3 Clock-
A21
LF Status
B21
LF Status
A22
Output Relay NO
B22
Output Relay NO
A23
CB Trip Status
B23
Reserved
A24
MC Coil Status
B24
Reserved
A25
MC Secondary Status
B25
Reserved
A26
FTR Coil Drive Status
B26
Reserved
A27
Door Switch Front
B27
Reserved
A28
Door Switch Rear
B28
Reserved
A29
Reserved
B29
DC MAINS Power
A30
Reserved
B30
No Connect
A31
Equipment Ground
B31
Reserved
A32
Reserved
B32
MAINS Ground
Note: Output Relay NO is open during FSA (de-energized).
6.2 CMUIP-2212 ETHERNET LAN PORT
The network port parameters can be set or changed using the EDI
ECcom
software. The
network port parameters can also be configured in the Datakey. See the
EDI ECcom
Operation Manual
(pn 888-1000-001) and
MonitorKey Operations Manual
(pn 888-
1212-001) for details.
The default network settings are:
IP Address
192.168.1.100
Subnet Mask 255.255.255.0
Gateway
none
6.2.1 ETHERNET LAN CABLE
The LAN cable required is a typical Cat-5 network cable using the 8 pin RJ-45 connector. If
the connection is from the monitor to a switch or hub, a standard LAN cable is needed. If
the connection is from the monitor directly to a network adaptor (PC), a cross-over or patch
cable is needed.