2.12.1 Electrical System Installation Procedures
Determine the location of the Relay and Fuse Holder wire harness. Most common
installations locate these components inside the driver’s compartment and close to the
fuse panel under the dash. You can also mount the Relay and Fuse Holder and
harness close to the battery. However, these connectors are water-resistant, not
waterproof, so care is required when mounting this assembly under the hood of your
vehicle.
Wire Schematic Origin and Destination Map
Wire Color System
Origin
Destination
Terminal Used
Red
Bat Voltage
Relay Harness
Bat. Volt. Signal
Ring
Red
Arming Switch
Underdash
Switched 12v
Spade/Wire Intercept
Black
Relay Ground
Relay Harness
Chassis Ground
Ring
Black
Solenoid Ground
Solenoids
Chassis Ground
Ring
Black
Arming Switch Ground Arming Switch
Chassis Ground
Ring
Blue
Solenoid Power
Relay Harness
Solenoids
Spade
White Microswitch
Relay
Harness Microswitch
Spade
White Microswitch
Arming
Switch Microswitch
Spade
2.13 Relay and Fuse Holder Installation
The wire harness attached to the relay and fuse holder includes 8 feet of color-coded wires to
make the electrical system installation for your Edelbrock Nitrous System as easy as possible.
We recommend you do not cut any lengths of wires from the wire harness or complete the
wiring of the nitrous system until all of the mechanical components are securely mounted in their
permanent locations.
Once all of the solenoids and switches are placed, then route the un-cut wires from the harness
to each location allowing enough wire length on each circuit to not interfere with operating
linkages, heat sources, brackets, etc. Pay particular attention to sharp edges along the route of
your wire harness, as they can chafe the wire and cause your system to fail.
After you have accounted for the routing of your wires, follow the Wire Harness Schematic on
page 18, and use the Origin and Destination Map as a guide for which electrical connectors are
used in each circuit.
Once you have determined the location of the relay and fuse holder, secure them with fasteners
(not included with kit) such as sheet metal screws, bolts and nuts, etc. Allow for some slack in
the red wire that connects the relay and fuse holders together.
When mounting your relay and fuse holder,
make sure the mounting surface is strong
enough to support servicing the relay and
fuse. Also, ensure you allow for some slack in
the wire that joins the fuse holder to the relay
mount. This will avoid any potential loss of
power due to stress on the wire harness.
The fuse is covered by the fuse mount
housing.
The relay for the Performer RPM System is 30
amps. The fuse is 15 amps.
Содержание 70050