background image

Power

(Signal connection) Short press 1second is connect the machine, the display will show 

“FHH” after connected, then “FHH” will change to special effects address as below show, that’s 

connected successful. Long press 3 seconds is unconnected, the display show “OFF”, then 
change to “001” as below:

HEAT ON/OFF:

 (Heat ON/OFF) Press button start to heat, red indicator light will lighting, the 

display will show heating temperature; long press 3 seconds is stop heating, the heat indicator is 

off, show the address code of the special effects.

STOP: 

(Emergency stop) Stop do fountain.

CLE:

 (Clear powder) The machine will do clear powder 30seconds automatically. (Please pour 

out the rest powder from powder box of machine before do this function)

HIGH1/HIGH2/HIGH3:

 (Fountain height) High 1 - fountain lowest, high 3- fountain highest

Speed:

  (Fountain  time  adjustment)  Multi-machines  do  fountain  effects,  the  fountain  time  of 

each machine is 1-3 seconds, can be adjusted by short press before do fountain.

L-R A:

 From left to right each machine do fountain on sequence.

LR-M A:

 From left & right side to middle, there have two machines do fountain at the same time.

M-LR A:

 From middle to left & right side, there have two machines do fountain at the same time.

L-R B:

 From left to right increase one machine do fountain, till all the machines in fountain.

LR-M B:

 From left & right side to middle increase two machines do fountain, till all the machines 

in fountain.

M-LR B:

 From middle to left & right side increase two machines do fountain, till all the machines 

in fountain.

HIGH1/2/3:

 Do special effects can adjust fountain height, will show different fountain height 

press every-time.

+NO.-:

 The number of machines be adjustment, how many machines you need used, then 

adjust the same number as used, the maximum add to fifteen machines.

DMX ADD

DMX ADD

Signal connected

successful

DMX ADD

DMX ADD

Signal

unconnected

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Содержание Pro EDDY-HW-01

Страница 1: ...MODEL EDDY HW 01 EDDYLIGHT PRO COOL SPARKLER MACHINE USER MANUAL...

Страница 2: ...ription 3 DMX address code adjustment PackageContents DMXInstruction 8 8 8 DMX ADD HEAT Means increasing DMX address code long press helps increase fast Means decreasing DMX address code long press he...

Страница 3: ...e is ready to work DMX Blue light Flashing shows that DMX signal is connected otherwise no signal FAULT Yellow light The light is on with any malfunction HEAT Red light When the machine is heating sig...

Страница 4: ...untain e ects the fountain time of each machine is 1 3 seconds can be adjusted by short press before do fountain L R A From left to right each machine do fountain on sequence LR M A From left right si...

Страница 5: ...e Remote controller Please ensure su cient consumables before use After added consumables Cover the rubber plug don t add to wrong fountain hole OperationInstruction The hole add consumables Power STO...

Страница 6: ...n indicator light always in lighting then can do fountain the display will show heating temperature Press special e ects A or B buttons will have related special e ects End of event Press CLE do clean...

Страница 7: ...No warranty service is provided for machines damage caused by consumables not from our company 1 2 Consumables Remark The detail channel instruction please refer to attached channel operation if need...

Страница 8: ...entsused avoidbestuckbyinside powder for next use The series of products designed two automatic modes of cleaning remaining consumables Operation step When the machine still in the preparatory state a...

Страница 9: ...ng failure 1 Check if the heat dissipation plate is normal 2 Replace the heat dissipation plate or heating board E03 1 Check the cooling fan 2 stop heating and operating restart after 10 minutes E02 H...

Страница 10: ...hine operation Warning Dangerous voltages are present in this machine when electrical power is applied There is a danger of injury from electric shock Under no circumstances are you to attempt to open...

Страница 11: ...tely turn o the power The heat dissipating fan should take out the internal air when the power is on Otherwise the internal heat is quickly transmitted to the surface of housing Please place the equip...

Страница 12: ...5 12 Power Switch DMX Port 6 13 Power Port Foldable Handle 7 14 Factory Code Access Hole 19 Cleaning hole Product Parameters Working Height Fountain Direction Working Temperature Heating Power Fuse 1...

Страница 13: ...rn o F6 136 159 Fountain 6 11 220 Emergency stop Add E57 F1 16 39 Fountain 1 F7 160 183 Fountain 7 221 239 Clear Powder CLE F2 40 63 Fountain 2 F8 184 207 Fountain 8 240 255 Pre heat turn on 0 500 F3...

Страница 14: ......

Отзывы: