background image

1

   

Suitable models instruction: 

this remote controller be suitable for all of models with remote 

function.

2

  

Buttons usage instruction:

 the remote controller include two parts, one for basic functions, 

another for special effects(the functions within black line)

READY

Green light

 When the "READY" green light turns from flashing into light on, it indicates 

that the machine is ready to work.

DMX

 Blue light

 Flashing shows that DMX signal is connected, otherwise no signal.

FAULT

Yellow light

 The light is on with any malfunction.

HEAT

 Red light

 When the machine is heating, signal light is on.

Indicator Description

Remote Controller

8 8 8

DMX ADD

HEAT

FAULT

DMX

READY

Power

STOP

HIGH

1

Speed

1/2/3

HIGH

2

HIGH

3

LR-M

A

L-R

A

M-LR

A

LR-M

B

L-R

B

M-LR

B

HIGH

1/2/3

+NO.-

CLE

HEAT

ON/OFF

Signal Connection

Emergency Stop

Heat ON/OFF

Clear Powder

Fountain Height

Number of Machines

Fountain Time

Special Effects A

Special Effects B

Fountain Height

Содержание Pro EDDY-HW-01

Страница 1: ...MODEL EDDY HW 01 EDDYLIGHT PRO COOL SPARKLER MACHINE USER MANUAL...

Страница 2: ...ription 3 DMX address code adjustment PackageContents DMXInstruction 8 8 8 DMX ADD HEAT Means increasing DMX address code long press helps increase fast Means decreasing DMX address code long press he...

Страница 3: ...e is ready to work DMX Blue light Flashing shows that DMX signal is connected otherwise no signal FAULT Yellow light The light is on with any malfunction HEAT Red light When the machine is heating sig...

Страница 4: ...untain e ects the fountain time of each machine is 1 3 seconds can be adjusted by short press before do fountain L R A From left to right each machine do fountain on sequence LR M A From left right si...

Страница 5: ...e Remote controller Please ensure su cient consumables before use After added consumables Cover the rubber plug don t add to wrong fountain hole OperationInstruction The hole add consumables Power STO...

Страница 6: ...n indicator light always in lighting then can do fountain the display will show heating temperature Press special e ects A or B buttons will have related special e ects End of event Press CLE do clean...

Страница 7: ...No warranty service is provided for machines damage caused by consumables not from our company 1 2 Consumables Remark The detail channel instruction please refer to attached channel operation if need...

Страница 8: ...entsused avoidbestuckbyinside powder for next use The series of products designed two automatic modes of cleaning remaining consumables Operation step When the machine still in the preparatory state a...

Страница 9: ...ng failure 1 Check if the heat dissipation plate is normal 2 Replace the heat dissipation plate or heating board E03 1 Check the cooling fan 2 stop heating and operating restart after 10 minutes E02 H...

Страница 10: ...hine operation Warning Dangerous voltages are present in this machine when electrical power is applied There is a danger of injury from electric shock Under no circumstances are you to attempt to open...

Страница 11: ...tely turn o the power The heat dissipating fan should take out the internal air when the power is on Otherwise the internal heat is quickly transmitted to the surface of housing Please place the equip...

Страница 12: ...5 12 Power Switch DMX Port 6 13 Power Port Foldable Handle 7 14 Factory Code Access Hole 19 Cleaning hole Product Parameters Working Height Fountain Direction Working Temperature Heating Power Fuse 1...

Страница 13: ...rn o F6 136 159 Fountain 6 11 220 Emergency stop Add E57 F1 16 39 Fountain 1 F7 160 183 Fountain 7 221 239 Clear Powder CLE F2 40 63 Fountain 2 F8 184 207 Fountain 8 240 255 Pre heat turn on 0 500 F3...

Страница 14: ......

Отзывы: