ECTIVE SC 20 Silent
37
Battery over-voltage
If there are other energy sources that charge the battery, when
the battery voltage exceeds 15 .8 / 31 .3V, the controller will
stop charging the protect the battery from damage due to
overcharging .
Battery over-discharge
When the battery voltage drops to the “low voltage disconnect”
value, the controller’s low voltage protection indicator will begin
to flash .
Over temperature protection
Integrated sensors allow the controller to measure the internal
temperature . When the temperature exceeds the setting value,
the charging current will decrease in order to reduce the heat .
When the internal temperature exceeds the over temperature
protection threshold, the controller stops working and will
resume operation only when the temperature has decreased
sufficiently .
Protection in case of damaged remote temperature sensor
If the external temperature sensor is short-circuited or
damaged, the controller will use the internal temperature for
charging temperature compensation .