4.1.3. RESET function
RESET
SELECT
Reset makes the device restart. The following actions follow:
-
Erased events counter.
-
The device restarts in LOCAL mode.
-
The RF output power recovers its level (before reset).
-
Transmission frequency does not change.
-
The calculation of the alarm threshold is made in AUTO.
-
Operation mode of the remote control restarts in normal mode.
4.1.4. STAND-BY mode
SELECT MODE
<- STAND-BY ->
There are major differences between “Stand-by” and “Shut down”.
Communication interfaces are still activated and the yellow LED “LOCAL” is on (the display switches off
after 10 seconds). Commands are accepted on every port.
4.2.
Selecting a mode
To switch from one mode to another, press the (ENTER) button located beneath the display. After
pressing it for 5 seconds, the mode menu appears.
•
LOCAL mode selection
Using (+) or (-) buttons, scroll the screens until the following message appears:
SELECT MODE
<- LOCAL ->
Press (ENTER) and the following message appears:
DISTANT LOCAL
ACTIVATED
The yellow indicator (LOCAL) switches on: You are now in maintenance mode. An RM output is used to
indicate the use of this mode - see figure ‘Maintenance menu".