38
7 - GAS SUPPLY PIPING
7.2 Gas Pipe Recommendations
Configure gas pipe for proper operation and avoid issues
with failure to light or maintenance of proper flame during
operation, which could cause error codes related to flame
signal.
•
Incoming pipe size and pressures shall be sufficient for
all gas appliances in the building. See Chart next page or
reference NFPA-54.
•
Use only properly rated and certified materials for gas pipe.
• Use of Schedule 40 metallic pipe and Corrugated Stainless-
Steel Tubing (CSST) is manufacturer recommended for
best performance.
•
Use of Gas Appliance Connectors (flexible connectors
typically used for gas stoves or water heaters) is
prohibited. Refer to national and local building codes.
•
Each fitting in the gas supply pipe shall count as 5
equivalent feet.
•
There shall be sufficient gas pressure at the boiler per gas
used and appliance rating plate.
• For LP applications there shall be no less than 10 linear
feet of properly sized gas pipe excluding fittings from the
closest regulator or meter in the gas supply piping.
ACCEPTABLE PIPING FOR
PROPANE
240013354 REV A [07/01/2021]
Содержание Utica Boilers MAC-115
Страница 2: ...MAC 205...
Страница 4: ...MAH 165...
Страница 77: ...73 APPENDIX A WIRING DIAGRAMS A 2 MODEL 125 Heat Only 240013354 REV A 07 01 2021...
Страница 78: ...74 APPENDIX A WIRING DIAGRAMS A 3 MODEL 165 Heat Only 240013354 REV A 07 01 2021...
Страница 79: ...75 APPENDIX A WIRING DIAGRAMS A 1 MODEL 115 Combi 240013354 REV A 07 01 2021...
Страница 80: ...76 APPENDIX A WIRING DIAGRAMS A 4 MODEL 150 Combi 240013354 REV A 07 01 2021...
Страница 81: ...77 APPENDIX A WIRING DIAGRAMS A 5 MODEL 205 Combi 240013354 REV A 07 01 2021...
Страница 115: ...32 CIRCULATOR CONNECTIONS WIRING DIAGRAM Single Zone Circulator Wiring Using ARGO AR822 II PN 240011430 REV O 07 01 2021...
Страница 117: ...34 MODEL 125 Heat Only 125 HEAT ONLY WIRING DIAGRAM PN 240011430 REV O 07 01 2021...
Страница 118: ...35 MODEL 165 Heat Only 165 HEAT ONLY WIRING DIAGRAM PN 240011430 REV O 07 01 2021...
Страница 119: ...36 115 COMBI WIRING DIAGRAM MODEL 115 Combi PN 240011430 REV O 07 01 2021...
Страница 120: ...37 MODEL 150 Combi 150 COMBI WIRING DIAGRAM PN 240011430 REV O 07 01 2021...
Страница 121: ...38 MODEL 205 Combi 205 COMBI WIRING DIAGRAM PN 240011430 REV O 07 01 2021...
Страница 126: ...43 Low Water Cutoff Detail LOW WATER CUTOFF NO NO YES PN 240011430 REV O 07 01 2021...
Страница 131: ...48 3 FAULT SOLUTION SECTIONS PN 240011430 REV O 07 01 2021...
Страница 134: ...51 Parameter ID Changed From Changed To Date Reason PARAMETER CHANGE HISTORY PN 240011430 REV O 07 01 2021...