Appendix A- HML-C AND HMLV-C
HML-C and HMLV-C furnaces may be used with the following oil burners.
Please note: The Beckett AF, and Riello 40F oil burners are for applications using indoor air for combustion only.
For sidewall venting applications utilizing outdoor air for combustion, use the Beckett AFII or the Riello 40BF
(Balanced Flue) oil burners only.
Table A-1 Beckett AF Oil Burner Set-Up
Beckett AF Series Oil Burners
(For use with chimney vented units only)
Furnace
Model
Output
BTU/Hr
Burner
Model
Nozzle
Pump
Pressure
Flow Rate
Head
1
Static
Plate
HML-60C
2
HMLV-60C ²
59,000
AF76BNHS 0.50 / 80°A
100
PSIG
0.50
USGPH
F3 3-
⅜
in.
HML-80C
HMLV-80C
75,000
AF76BNHS 0.65 / 80°A
100
PSIG
0.65
USGPH
F3 3-
⅜
in.
HML-90C
HMLV-90C
86,000
AF76BNHS 0.75 / 80°A
100
PSIG
0.75
USGPH
F3 3-
⅜
in.
HML-100C
HMLV-100C
95,000
AF76BNHS 0.85 / 70°A
100
PSIG
0.85
USGPH
F3 3-
⅜
in.
1
Head is shielded by ceramic insulator.
2
Low Firing Rate Baffle required when using a 0.50-gallon
nozzle.
Table A-2 Beckett AFII Oil Burner Set-Up
Beckett AFII Series Oil Burners
(For use with sidewall vented units with outdoor combustion air, or chimney vented units with indoor air
for combustion)
Furnace
Model
Output
BTU/Hr
Burner
Model
Nozzle
Pump
Pressure
Flow Rate
Head
HML-60CB2U
HMLV-60CB2U
63,000
AFII-85
0.50 / 60°A
120
PSIG
0.55
USGPH
FB0
HML-80CB2U
HMLV-80CB2U
75,000
AFII-85
0.60 / 60°A
115
PSIG
0.65
USGPH
FB3
HML-90CB2U
HMLV-90CB2U
86,000
AFII-85
0.70 / 60°A
115
PSIG
0.75
USGPH
FB3
30173 Rev B 4/29/2008
10