background image

Please read carefully prior
to installing and servicing.

SAVE THESE INSTRUCTIONS

Operating

Manual

Pellet heating with auger
delivery or vacuum suction
system for the end-user

AutoPellet Air Furnace

17 — 28

FA_V2.05

AutoPellet Air TOUCH

USA

PE 604 USA_FA 1.0

·

www.maineenergysystems.com

Содержание AutoPellet Air TOUCH 17

Страница 1: ...and servicing SAVE THESE INSTRUCTIONS Operating Manual Pellet heating with auger delivery or vacuum suction system for the end user AutoPellet Air Furnace 17 28 FA_V2 05 AutoPellet Air TOUCH USA PE 6...

Страница 2: ...04 USA_FA 1 0 Version valid from 07 2015 Approved Wohlinger Christian Author Manufacturer MAINE ENERGY SYSTEMS LLC 8 Airport Road P O Box 547 Bethel Maine 04217 E Mail info maineenergysystems com MAIN...

Страница 3: ...e 1 18 8 7 1 Pellet suction system 20 7 1 1 Assembly of the vacuumsystem 20 7 2 Storage systems 22 7 2 1 Flexilo textile tank 22 8 8 O Op pe er ra at ti in ng g t th he e F Fu ur rn na ac ce e 2 23 3...

Страница 4: ...r re e 5 59 9 1 18 8 M Ma ai in nt te en na an nc ce e a an nd d s se er rv vi ic ci in ng g 6 60 0 18 1 Cleaning the Furnace every year 60 18 2 Maintenance intervals 63 18 3 Repairs 63 18 4 Checking...

Страница 5: ...a safe place for future reference Please pass on the documentation to the new user if you decide to part with the unit at a later date Installation and first start up must be carried out by an instal...

Страница 6: ...the purpose intended The pellet furnace is designed heat air to provide heat for buildings It is not permissible to use the furnace for any other purpose The pellet furnace fulfils the requirements o...

Страница 7: ...ad to death or life threatning injury Warning indicates a situation that could lead life threatning or serious injury Caution indicates a situation that could lead to injury Note indicates a situation...

Страница 8: ...lation systems central vacuum cleaning systems extractor fans air conditioning systems flue gas blo wers dryers fuel storage ventilation fans or similar equipment must never be allowed to draw air fro...

Страница 9: ...ng so can allow non controlled combustion R Ri is sk k o of f c cu ut t i in nj ju ur ri ie es s d du ue e t to o s sh ha ar rp p e ed dg ge es s Use gloves for performing all work on the Furnace D Da...

Страница 10: ...ety the utmost priority What to do in the event of a fire Switch off the heating system Call your local fire department and or 911 Use approved fire extinguishers fire protection class ABC What to do...

Страница 11: ...anges shall comply with the Canadian Electric Code Part 1 5 2 Furnace room circulating air The pellet Furnace is installed in the Furnace room 1 Safety instructions for the Furnace room R Ri is sk k o...

Страница 12: ...ially or completely closed Contaminated combustion air can cause damage to the pellet Furnace Never store of use cleaning deter gents containing chlorine nitrobenzene or halogen in the room where the...

Страница 13: ...load part load in wc 0 04 0 02 Chimney size Min Height 6in x 6in 17ft 7in x 7in 16ft 8in x 8in 16ft 6in round 19ft 7in round 17ft Person s operating a pellet fired furnace is are respon sible for ope...

Страница 14: ...tion This may only be performend by authorised personnel 4 Power venter AutoPellet Air are approved by the manufacturer for installation with the Field Con trols SWGAF power venter which is approved f...

Страница 15: ...ecifications the appliance in question is installed in a manner commonly recognized as safe and correct for the application and circumstances The chimney or flue gas system must be able to handle the...

Страница 16: ...sp pe ec ci if fi ic ca a t ti io on ns s U Us si in ng g n no on n p pe el ll le et ti is se ed d f fu ue el ls s o or r p pe el ll le et ts s t th ha at t a ar re e n no ot t m ma an nu uf fa ac ct...

Страница 17: ...untry must be observed regarding building specifications for storage rooms 5 koFEN also offers FleXILO fabric tanks for storing pellets 6 3 Measures for the ventilation of storage rooms To avoid any k...

Страница 18: ...ce with the following power ratings Suction feed systems 58 000 to 95 000 BTU hr All sizes outputs of the AutoPellet Air Furnace are available with external automatic ash compression system Note Refer...

Страница 19: ...ash box optional 3 Flame tube 11 Burner fan 4 Heat exchanger 12 Burner auger 5 Flue gas fan 13 Electronic ignition 6 Combustion chamber cover 14 De ashing system optional 7 Suction turbine 15 Ash cham...

Страница 20: ...eet Note A difference in height of up to 10 feet can be overcome at one time Larger diffe rences in height must by interrupted with a 4 foot horizontal run of the pellet hose Impact protection The spi...

Страница 21: ...spiral hose The maximum total length of the spiral hose is 130 feet The maximum for pellet hose and air hose are each 60 feet Assembly Use securing clips and carrying bowls Pay attention to the define...

Страница 22: ...r ra an nt ty y The use of an AutoPellet Air Furnace with a storage or conveyor system from another manufacturer is not per missible and will result in voiding your warranty along with undependable op...

Страница 23: ...nc co or r r re ec ct t s se et tt ti in ng gs s Only trained operators may use the heating system Make sure no unauthorised persons enter the central heating room Keep children away from the central...

Страница 24: ...e flap above the door of the Furnace 1 User control unit Operates the Furnace controller 2 Main switch Switches off the heating system both po les including the power supply to the con trol panel 3 Sa...

Страница 25: ...uage date and time at Pelletronic Touch 25 8 3 Setting language date and time at Pelletronic Touch Setting the language The factory setting for the language is German Operating Manual AutoPellet Air F...

Страница 26: ...26 Setting language date and time at Pelletronic Touch Setting the date Setting the time PE 604 USA_FA 1 0...

Страница 27: ...not flammable steel container Do not use ash container to store waste or other material Do not empty ash onto flammable floors or materials Emptying the ash pan Note Check the level of the ash pan and...

Страница 28: ...is installed An external ash box can also be retrofitted D Da am ma ag ge e t to o p pr ro op pe er rt ty y Empty the ash box before a longer off time of the Fur nace Otherwise the auger and the open...

Страница 29: ...the ash box Note When the ashbox is full then Ash appears on the display with the alarm text Ash box full After emptying and restarting the ash box the alarm text disappears automatically Operating Ma...

Страница 30: ...g device 9 1 Opening window The touch panel is dark during in standby mode As soon as you touch the surface of the touch light turns on and displays the opening window 1 Measuring values adjustable 2...

Страница 31: ...ly to the main menu The horizontal arrow leads you one step back With the blue down arrow you get to additional lines of information on this item Down scroll down With the blue up arrow you get to add...

Страница 32: ...ard used to enter values within the min max range 3 Time and date block a Adjustable time or date b Cancel c Help function inactive d Confirm With the Plus Minus block you change numbers 4 Text select...

Страница 33: ...Menu 33 9 3 Main Menu In the Main menu you see all submenus By finger pressure on an icon you reach the respective submenu Menu navigation of Pelletronic Touch Operating Manual AutoPellet Air Furnace...

Страница 34: ...menu item Mode is in the Main menu Overview of the operating modes Heating Plant Heating system 1 6 Furnace Choose the operating modes and make settings Off The adjusted operating mode of the heating...

Страница 35: ...enu item Measuring Values is in the Main menu Furnace Heating circuit Heating Plant Allocation Status In the menu item Allocation you see which heating circuits are allocated to the Furnace or to the...

Страница 36: ...ound enter a larger nearby place Search with the following details Postal code location country Postal code country Location country Afterwoods weather data for the next 3 days are downloaded An icon...

Страница 37: ...ther data for the next 3 days are downloaded An icon for the current weather is displayed on the opening window Note This feature requires an internet connection Cur temperature Current temperature ac...

Страница 38: ...ace starts in the heating times according to the Set room temperature Heating The Furnace heats constantly according to the Set room temperature Set back The Furnace heats constantly according to the...

Страница 39: ...Inputs sensores Outputs pumps mixer and motors Outside Temperature actual Outside Temperature Furnace Temp actual Furnace Temperature Existing Furnace actual Temperature of available Furnaces Booster...

Страница 40: ...g times 3 Enter the heating times for these hea ting days Mo Th 8 With and you switch between the heating blocks You can deactivate heating days in the heating block and activate in another 4 The heat...

Страница 41: ...e party function deactivates itself automatically 14 4 Vacation The holiday programme cancels the heating times and heats for the entered period on the set temperature level Vacation is in the Main me...

Страница 42: ...ion between outdoor temperature and the associa ted flow temperature for a heating circuit Base point adjustable from 68 113 F With the change the of base point you provide a parallel shift of the hea...

Страница 43: ...to reach the adjusted roomtemp heating Room thermostat influence If the measured room temperature deviates from the set room temperature the heating controller corrects the flow temperature with the R...

Страница 44: ...e Room temperature hysteresis prevents the cycling On Off On Off of the heating circuit pump If the Set room temperature room temperature hysteresis is reached the associated pump stops If the Set roo...

Страница 45: ...the Main menu Furnace has following items Operation Mode Measuring values Locktime Continuous running Full power Filling level Fan Suction turbine 15 1 Measuring values Measuring values is in the men...

Страница 46: ...Furnace First of all the spring driven motor opens the fi re protection system at the burner the process takes about 2 minutes After that the burner motor runs in permanent operation and transports p...

Страница 47: ...teps up or down 15 5 Fan Fan is in the menu Furnace Off Function fan inactive Auto The function of the fan or blower is automatic On Function fan active When reaching the On Temp the output UW is acti...

Страница 48: ...sing the wrong pump type The pump switches off after falling below the On Temp from minus Switch Off Hyst Is the Control Range of output UW at cycling mode The speed controller starts at the Furnace t...

Страница 49: ...time matches the time set in the Cleaning Filling menu and can be set at either menu Frequency for storage room suction systems in pulse mode only for vacuum systems Pause time for storage room extrac...

Страница 50: ...ions for the customer General is in the Main menu The menu General includes Chimney Favorit Values Local setting Malfunction Info ModBUS E Mail IP Config 16 1 Chimney The function chimney is only for...

Страница 51: ...e function chimney ends time of expiry the operation Chimney sweeper ends The button Cancel ends the function Chimney 16 2 Favorite Favorite is in the menu General With this function you can display m...

Страница 52: ...tings has following menu items Language Unit Date Time Choose between the languages German English UK English U S French Spa nish Italian Dutch Danish and Russian You can choose between isometric and...

Страница 53: ...remains until it is acknowledged The menu remains the fault incident reports as long as they are corrected up 16 5 Information Information is in the menu General In the menu item information are all f...

Страница 54: ...54 ModBUS 16 6 ModBUS Off TCP Server Defaultport for ModBUS is 502 PE 604 USA_FA 1 0...

Страница 55: ...of disturbance emails is done through an Maine Energy system server Only the recipient address needs to be configured To ensure maximal flexibility E mail settings can set individually Operating Manua...

Страница 56: ...workmask is required in the local network GW The gateway enables the touch operating device the access to the internet D1 D2 Server which provide routing information Set DHCP On or Off depending on yo...

Страница 57: ...ial services e g 25 Mail 80 Web and so on The ping prevents the internet connection from beeing closed by the router Therefore a query to the Maine Energy Systems server is started at certain time int...

Страница 58: ...stems can not be used But the remote controll of the Touch operating device remains active and can be uses as before via port forwarding DynDns fixed external IP LAN and so on All functions for the ne...

Страница 59: ...Software 59 1 17 7 Software Software is in the Main menu Software shows you the name of the current software Operating Manual AutoPellet Air Furnace 17 28...

Страница 60: ...rt t o of f t th he e h he ea a t ti in ng g s se ea as so on n C Cl le ea an ni in ng g o of f t th he e p pe el ll le et t F Fu ur rn na ac ce e h ha as s t to o b be e p pe er rf fo or rm me ed d f...

Страница 61: ...aning the Furnace every year 61 Note Check first of all if all seals are in a good condition and the doors closes tightly Procedure for cleaning the Furnace Operating Manual AutoPellet Air Furnace 17...

Страница 62: ...an nd d d da am ma ag ge e t to o p pe el ll le et t F Fu ur rn na ac ce e d du ue e t to o b bl lo oc ck ka ag ge es s i in n t th he e a ai ir r i in nl le et t Clean the air intakes the burner pla...

Страница 63: ...storage room Checking the pellet heating system regularly prevents malfunctions and unexpected failure of the heating system Furnace room Make sure that no flammable materials are stored in the Furnac...

Страница 64: ...Ri is sk k o of f s su uf ff fo oc ca at ti io on n Ventilate the pellet storage room sufficiently before entering Switch off the heating system before entering Check the level of pellets in the texti...