Safety systems
15
5.5 Safety systems
The following safety measures are the prerequisite for safe operation of your system.
Emergency stop switch
Every heating system must be able to be switched off with an Emergency Stop switch. The
Emergency Stop switch must be outside of the Furnace room.
Safety temperature sensor
The pellet Furnace is equipped with a safety temperature sensor. This is located on the pel-
let Furnace. If the Furnace temperature exceeds 230°F then the heating system switches
off.
5.6 Installation with an existing Furnace
AutoPellet Air Furnaces are not to be connected to a chimney flue serving another appliance. However, when
all State and local codes allow for the sharing of chimney flues, the AutoPellet Air Furnaces and another appli-
ance burning pellets or a different fuel can be operated simultaneously while connected to a single existing
chimney or flue gas system providing the following conditions are met:
• All state and local codes permit the specific installation
• All appliances are installed in accordance with the manufacturer’s installation specifications or if lacking
manufacturers specifications, the appliance in question is installed in a manner commonly recognized as
safe and correct for the application and circumstances
• The chimney or flue gas system must be able to handle the combustion products of either appliance and
both appliances when operated simultaneously
A
Av
vo
oiid
d c
clle
ea
arra
an
nc
ce
e iissssu
ue
ess tth
ha
att c
ca
an
n m
ma
ak
ke
e sse
errv
viic
ciin
ng
g d
diiffffiic
cu
ulltt::
Be sure to follow suggested clearances when installing the Au-
toPellet Air Furnaces with an existing Furnace to be sure that
service and cleaning can be performed adequately.
A
Av
vo
oiid
d c
co
od
de
e v
viio
olla
attiio
on
nss::
When connecting to or with an existing Furnace , contact the au-
thority having jurisdiction to be sure the type of installation plan-
ned is allowed.
Document the type of Furnace that the AutoPellet Air Furnace is
connected to or with.
Pellet Furnace: Make and Model number:
____________________
Existing Furnace: Make and Model number:
_____________________
P
Po
ossssiib
blle
e e
essc
ca
ap
pe
e o
off ffllu
ue
e g
ga
ass::
Do not connect this unit to a chimney flue serving another appli-
ance unless multiple appliances into a single flue is authorized by
all authorities having jurisdiction.
Operating Manual AutoPellet Air Furnace 17 — 28