58
IP Config
The port of the touch panel must correspond to the external shared
port.
The touch then registers with the external IP address and port on Ök-
oFEN remote maintenance server.
In case of change of address by the external provider, this is detected
and sent to the Maine Energy Systems server.
Static
In this mode, no connection data is transferred to the Maine Energy
Systems server and the online service of Maine Energy Systems can
not be used.
But the remote controll of the Touch operating device remains active
and can be uses as before via port forwarding, DynDns, fixed external
IP, LAN and so on.
All functions for the network/internet can be disabled here.
Remote maintenance access
This function determines the network settings automatically.
For this the DHCP mode is activated and the required settings are set
automatically.
Afterwards DHCP is deactivated.
Because of this, the IP address of the contol unit can change.
The settings are set as follows:
• DHCP Off
• Ping On
• Port 8080
• Remote maintenance: Automatic
Back to the menu
General
.
PE 604 USA_FA 1.0