ECOWATER
S Y S T E M S
English
42
Table 1. Temperature correction factors
°C
TCF (25°C standard) TCF (15°C standard)
5
2,08
1,54
7
1,92
1,41
10
1,71
1,24
11
1,63
1,19
14
1,48
1,04
15
1,42
1,00
16
1,37
0,97
19
1,24
0,88
20
1,19
0,86
25
1,00
0,74
26
0,97
0,71
29
0,89
0,65
30
0,86
0,64
Example
:
RO
unit 4002
Production flow
0,45 m³/h
Permeate preesure 0,35 bar
Feed pressure
11,7 bar
Temperature
16°C
Net operating pressure
= 11,7 – 0,35 = 11,35 bar
Pressure compensated flow rate
= 0,45 x 8,6 / 11,35 = 0,340 m³/h
Temperature compensated flow rate = 0,34 x 1,37 = 0,465 m³/h
When the compensated flow decreases by 10% or more or the product TDS increases by 10%, membrane
cleaning should be scheduled.
With aging of the membranes there will also be a gradual decline in production flow. Thus, the age of the
membranes should also be taken into account. In general, there is a loss of production of:
Age
Production
loss
6
months
7%
1
year
12%
3
years 17
%
4.17 FILTER CARTRIDGES
The supplied filter cartridges have a 5 micron sieve. They must be replaced when the pressure drop across
the filter cartridge exceeds 0.7 bar or if they are discolored. The prefilters are placed to protect the membra
-
nes and should therefore be properly checked.
4.18 CHEMICAL INJECTION SYSTEMS
Dosage devices for dosing anti-scalent should be checked regularly for their proper functioning. The dosing
pump can draw air or get contaminated with eg sand particles. These dosages also serve to protect the mem-
Содержание ROHD 4000
Страница 16: ...ROHD SB ROHD 4000 Rev 19 09 2017 MANUEL D UTILISATION EcoWater Systems Europe www ecowater be ...
Страница 31: ...ROHD SB ROHD 4000 Rev 19 09 2017 USER GUIDE EcoWater Systems Europe www ecowater be ...
Страница 46: ...ECOWATER S Y S T E M S 46 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD SB ...
Страница 47: ...ECOWATER S Y S T E M S 47 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD SB ...
Страница 48: ...ECOWATER S Y S T E M S 48 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD SB ...
Страница 49: ...ECOWATER S Y S T E M S 49 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD SB ...
Страница 50: ...ECOWATER S Y S T E M S 50 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD 4000 ...
Страница 51: ...ECOWATER S Y S T E M S 51 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD 4000 ...
Страница 52: ...ECOWATER S Y S T E M S 52 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD 4000 ...
Страница 53: ...ECOWATER S Y S T E M S 53 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD 4000 ...
Страница 55: ...ECOWATER S Y S T E M S 55 Your Water Perfected ...