ERO335 MAINTENANCE  

 

  
 

To  keep  the  RO  water  system  operating  and  making  high  quality  water,  the  RO,  prefilter,  and  postfilter 
cartridges need replacement at regular intervals. Depending on water supply quality, the prefilter and postfilter 
cartridges may last for 6 months to 1 year. RO cartridge life normally ranges between 36 and 60 months. 
 
This reverse osmosis system contains a replaceable 
treatment  component  critical  for  effective  reduction 
of total dissolved solids (TDS). The water should be 
tested periodically to verify the system is performing 
satisfactorily. 

 

 

Prefilter  Cartridge: 

You  must  replace  the  prefilter 

cartridge often 

to protect  the RO membrane from 

being destroyed by chlorine,

 

and/or from plugging 

with  sediments  in  your  water  supply.  If  the  water 
supply  contains  both  chlorine  and  sediments, 
replace  the  prefilter  cartridge  at  least  every  6  -  12 
months.  Replace  more  often  than  6  months  if  it 
begins to plug with sediments. 
 
If  the  water  has  sediments  only,  with  no  chlorine, 
you may notice a slower making of product water as 
the  prefilter  collects  the  sediments.  When  this 
occurs, replacement is needed to restore full flow. 
 

Postfiliter Cartridge: 

The carbon postfilter removes 

any

 

remaining  taste  and/or  odors  from  the  product 

water  before  it  goes  to  the  RO  faucet.  Replace  the 
cartridge  when  the  taste  and/or  odor  returns  in  the 
RO water, typically every 6 to 12 months. 
 

RO  Membrane  Cartridge: 

The  life  of  the  RO 

cartridge depends mostly on properly treated supply 
water  and  regular  maintenance  of  the  prefilter 
cartridge. The membrane has a self-cleaning feature 
that,  under  typical  conditions,  extends  life  to 
between 18 and 36 months. Replacement of the RO 
cartridge  is  made  when  testing  indicates  TDS 
rejection  is  not  within  specifications.  Product  water 
may begin to taste different or bad, indicating solids 
and  organics  are  passing  through  the  RO 
membrane. To be sure it is the RO cartridge, always 
replace the prefilter and postfilter cartridges first. 

Содержание ERO335

Страница 1: ...ften than 6 months if it begins to plug with sediments If the water has sediments only with no chlorine you may notice a slower making of product water as the prefilter collects the sediments When this occurs replacement is needed to restore full flow Postfiliter Cartridge The carbon postfilter removes any remaining taste and or odors from the product water before it goes to the RO faucet Replace ...

Страница 2: ...en turn 1 4 turn to the left the cartridge and pull downward 3 Depress the elbow fitting collet with a finger while carefully pulling the red tubing out 4 Remove the new RO cartridge from the sanitary bag Rinse the cartridge in fresh tap water and dry Depress the elbow fitting collet and remove the plug 5 Remove the protective cap not shown from the top end of the cartridge Be sure the o ring seal...

Страница 3: ...e storage tank is completely empty and the bleach odor is gone 9 Close the RO faucet after water flow stops LEAK AT FAUCET If the sink p trap is used as the drain point RO reject water is routed to the faucet air gap through 1 4 tubing It gravity drains from the faucet through 3 8 tubing to the drain point The hole in the faucet body below the lever is the air gap vent If the 3 8 tubing is restric...

Страница 4: ...Holmes Ecowater Phone 403 327 7867 Toll Free 877 327 9007 925 2 A Ave N Lethbridge AB mailto tech holmeswater com MAINTENANCE RECORD Date PreFIlter Post Filter Membrane Sanitized ...

Отзывы: