background image

 

 

 

 

Iron Trapper™ Installation & Start-Up Procedures 

 

Congratulations! 

 

You’ve selected our best-selling 
well water treatment system for 
top performance and economy.   

 

Iron Trapper™ systems reduce 
Iron, Hydrogen Sulfide and 
Manganese and are designed to 
provide years of service with 
proper care and maintenance.   

 

Hopefully, this manual will be 
beneficial and provide information 
you need to install, start-up and 
maintain your system.  
 
 

®2020 Safety Zone Water Systems, LLC 

 

Valve type 

Metered 

Valve sizes 

1”, 1.25”, 1.5” and 2” 

Pipe fittings available 

¾”, 1”, 1.25” and 1.5”  

Filtration procedure 

“Air Draw” for oxidation 

Riser tube size 

1.05”, 1.25”, 1.5” and 2” 

Drain line fitting 

¾” male NPT 

Brine line (for air draw) 

3/8” quick connect 

Supply voltage 

120 V AC 

Supply frequency 

60 Hz 

Output voltage 

12 V AC 

Filtration media 

For Iron, Hydrogen Sulfide & Mang. 

By-pass valve 

Included 

 

 

Specifications 

 

How it works! 

The Iron Trapper™ utilizes oxygen, 
contained in your water and fresh 
ambient air injected inside the filter 
tank to oxidize Iron, Hydrogen Sulfide 
and Manganese, so they drop out of 
solution to form particles.  These 
particles are trapped by the filter 
media, and are periodically removed 
from the filter during the

 

backwash 

cycle. 
 
Iron Trapper™ systems do not need 
chemicals for 

oxidation

.  However, if 

your water contains bacteria, water 
treatment chemicals may be required 
for 

disinfection

 

 

Proper Well water treatment 

Proper well water treatment is based on 

what’s in your water.  Challenges include 

water hardness, Iron, Hydrogen Sulfide 

(rotten egg odors), sediment, tannins, 

Arsenic, Nitrates, Acidic water (low pH), 

bacteria and other harmful 

microorganisms.  

 

Iron Trapper™ for Iron & 

Hydrogen Sulfide  

(Sulfur Odors) 

 

This unique system removes Iron, 

Hydrogen Sulfide and Manganese using 

our AIR DRAW valve for greater oxidation.  

 

To view our valve manuals visit 

www.safetyzonewater.com

 

 

 

Содержание Iron Trapper ISF-150-AD

Страница 1: ... By pass valve Included Specifications How it works The Iron Trapper utilizes oxygen contained in your water and fresh ambient air injected inside the filter tank to oxidize Iron Hydrogen Sulfide and Manganese so they drop out of solution to form particles These particles are trapped by the filter media and are periodically removed from the filter during the backwash cycle Iron Trapper systems do ...

Страница 2: ...ue backwash until the drain water runs clear This may take some time 10 Advance to the draw cycle to create an air pocket in the filter tank 11 The 2nd backwash should be turned OFF 12 The rinse cycle should be turned OFF 13 For the refill cycle set the salt level at ZERO to deactivate this cycle 14 When the valve goes into service open outlet on the valve to supply water to the house Valve Progra...

Страница 3: ...to complete a water test prior to start up and valve programming Check the following parameters Hardness pH Iron well water Hydrogen Sulfide well water Manganese if common in the area System placement 1 Locate main water line and determine where to place the unit near power outlet and location for the drain 2 Install system on main water line before the water heater Be sure the by pass is closed I...

Страница 4: ...y 1 3 to fill mineral tank 4 Allow air to escape listen until spurting stops 5 When water flows from drain open inlet valve fully 6 Make sure drain line is not restricted Note Do not tee drain line with a softener 7 Continue backwash until water runs clear 8 Press and release REGEN to advance to the DRAW cycle to create an air pocket in the filter tank 9 Press and release REGEN to advance to the 2...

Отзывы: